Owner`s manual
Page 13
H-Series DL Gas Fireplace
Part No. XG0140 - 092210
18”
25”
A
C
B
Horizontal Run (in.)
Vertical Height (in.)
34”
46”
18”
27 3/4”
A
C
B
Horizontal Run (in.)
Vertical Height (in.)
34”
50”
Installation
Figure 16. H34DL* Rear Vent Venting Graph for wall mounted
terminations, See Figures 18a & 18b.
Notes Wall Mounted Terminations: Rear Vent
All dimension lengths for vertical or horizontal runs are measured
from center of the vent pipe.
Venting runs must fall within the limits set by the venting graphs,
see Figure 16, 17 & 18.
Fireplace must be converted to Rear Vent conguration prior to
running vent, see Figure 7 and 8.
The Venting Graph H34DL*
Measure the vertical height from the replace hearth to the centre of the
termination and the horizontal run from the replace ue collar to the wall
ange of the termination. Plot on the Venting Graph Figure 16 with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 60" and the horizontal
run to the wall ange of the vent termination is 24", this would be
an acceptable installation.
Example B: (Acceptable Installation)
If the vertical dimension from the hearth is 78" and the horizontal
run to the wall ange of the vent termination is 60", this would be
an acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the oor of the replace is 60" and
the horizontal run to the wall ange of the vent termination is 120",
this would NOT be an acceptable installation.
If your installation does not fall within
the venting graph parameters, (non-
Shaded area) please contact Montigo
for Power Venting options.
Acceptable Vent run
within non-shaded area.
The Venting Graph: H38DL*
Measure the vertical height from the replace hearth to the centre of the
termination and the horizontal run from the replace ue collar to the wall
ange of the termination. Plot on the Venting Graph Figure 17 with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 84" and the horizontal run to
the wall ange of the vent termination is 36", this would be an acceptable
installation.
Example B: (Acceptable Installation)
If the vertical dimension from the hearth is 108" and the horizontal run to
the wall ange of the vent termination is 144", this would be an acceptable
installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the oor of the replace is 72" and the
horizontal run to the wall ange of the vent termination is 108", this would
NOT be an acceptable installation.
If your installation does not fall
within the venting graph para-
meters, please contact Montigo
for Power Venting options.
Unacceptable vent run
within shaded area.
Acceptable vent run
within non-shaded area.
Figure 17 H38DL* Rear Vent Venting Graph for wall mounted
terminations, See Figures 18a & 18b.
Acceptable vent run
within non-shaded area.