Owner`s manual
Page 15
H-Series DL Gas Fireplace
Part No. XG0140 - 092210
Figure 18c. Corner installation.
Figure 18d. Flex installation. (NG Models Only)
45° Corner Installation.
Attach an MEL-45 / PEL-45 (45° elbow) directly onto the ue collar.
Cut the MXT-20 / PXT-20 to suit, and attach it to the MEL-45 / PEL-
45. Slide the replace into position and attach to the termination.
45° or less Corner Installation.
Use an MTO-4 / PTO-4 termination and an MFL-1 / PFL-1 or MFL-2
/ PFL-2 (12" or 24" compressed length) and a frame, if appropriate.
Flex may be turned to obtain desired degree of angle required but
must not exceed 45°.
Note: Through the wall venting kits are also available for both
the Straight and the Corner Installation. The Kit includes a heat
shield, a MFL-12 (f/f) / PFL-12 (f/f) exible pipe, and a termination
with or without a mounting frame.
Installation
Rigid Section
Rigid Elbow
Flex Section