Installation Operation & Maintenance H34D Gas Fireplace Warning: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. What To Do If You Smell Gas: For Your Safety: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. • Do not try to light any appliance.
H34D Gas Fireplace Table Of Contents Introduction Thank You for choosing a Montigo Gas Fireplace. Introduction ............................................................................ 2 About this Fireplace: Installation The H34D is an 18,000 BTU fireplace with a pan-style burner and glowing embers. This fireplace can be converted to both a Top Vent or Rear Vent application, and it is available in two models.
H34D Gas Fireplace Installation Installing The Fireplace Shell Framing The fireplace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumbing. Safety, as well as efficiency of operation, must be considered when selecting the fireplace location. Try to select a location that does not interfere with room traffic, has adequate ventilation, and offers an accessible pathway for Direct Vent installation.
H34D Gas Fireplace Installation Installing The Gas Line The gas line must be installed before finishing the H34D Fireplace. Natural Gas requires a minimum inlet gas supply pressure of 5.5" W.C. & a manifold pressure of 3.5" W.C. Propane Gas requires a minimum inlet gas supply pressure of 11" W.C. & a manifold pressure of 10" W.C. Provision must also be made for a 1/8" N.P.T. plugged tapping and be accessible for test gauge connection immediately upstream of the gas supply controls to the appliance.
H34D Gas Fireplace Installation Installing Terminations with Built-In Frames Installing Heat Guards over Terminations 11 MTO-3F 11 MTKOG 1. Frame the termination opening to 11" x 11". 2. Fasten the termination to the studs using a minimum of 4 screws. 1. Ensure that the two long mounting brackets are facing the bottom of the termination. (See inset). This will provide more heat protection at the top of the termination, where temperatures are highest. 2.
H34D Gas Fireplace Installation Converting to Top Vent/ Rear Vent H34DL Top Vent Use the following instructions to convert an H34DL for Top Vent use: 1. Install the 4" inner flue cap on the rear flue outlet and secure the cap in place with five screws, as shown in figure 7a. 2. Install the 7" outer flue cap on the rear flue outlet, and secure it with five screws, as shown in figure 7a. H34DL Rear Vent Use the following instructions to convert an H34DL for Top Vent use: 1.
H34D Gas Fireplace Installation Top Vent Venting Runs Before you install any venting, you must determine whether the venting run will be acceptable. Unacceptable venting can affect the fireplace's combustion.
H34D Gas Fireplace Installation Example 1: For our shortest venting configuration use components A and E (see Figure 9a). Figure 11. Typical Top Vent installation. If the 90° elbow is installed directly on the fireplace, the height to the center of the termination is 42 1/4". Horizontal Venting Figure 13. Extended Installation using a combination of solid and flex venting. Use the vent graph to determine your allowable run, then select appropriate components.
H34D Gas Fireplace Installation B. Vertical (Through-The-Roof) Installations ■ Vertical Terminations must be installed: • minimum 2' (two feet) above the highest point where vent passes through the roof. • minimum 6' (six feet) from a mechanical air inlet • minimum 18" (1 1/2 feet) from a parapet wall. ■ Maximum vent height is 32 feet above fireplace. Note: Flame characteristics will change if the maximum vent height is used.
H34D Gas Fireplace Installation Rear Vent Venting Runs The H34DL Rear Vent has three possible installations which do not require vertical lift, all of these installations require that you install the RHS101 heat sheild. Heat Shield The heat shield (RHS101) must be used on all installations straight through the wall, at the point where the vent pipe connects to the termination. With the heat shield, proper vent clearances can be maintained. The heat shield is not included with the fireplace. 2.
H34D Gas Fireplace Installation B. Multi-Elbow Installations For more diffiicult installation situations, the H34D Rear Vent may be installed with two — 90° elbows and up to 15' of horizontal run. If using this installation option, you must adhere to the following guidelines: ■ the first 90° elbow must be placed directly on the flue collar Installation Of Rear Vent DV H34D Rear Vent versions are supplied with an EXT-18 (female/female) section.
H34D Gas Fireplace Installation Finishing Around the Fireplace Combustible mantels and mouldings may be safely installed over the top and on the front of the fireplace provided that they do not project beyond shaded area shown in Figure 23. Side wall clearances are 3". Combustible surrounds may be installed with 3" clearance to the side of the fireplace as shown in Figure 24.
H34D Gas Fireplace Installation Wiring for the optional Fan Kit Removing and Installing the Door All H34D fireplaces may be equipped with optional fan kits for circulating heat into the living space. Removing the door: Installations in Canada which employ the fans must be electrically grounded in accordance with CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes. The door is held in place by a lip on the top of the metal frame and two buckles at the bottom.
H34D Gas Fireplace Installation Installing the Log Set Installing the Log Logs: 'D' The H34DF is supplied with four ceramic fibre logs and a ceramic fibre logset base. Unpack the logs and handle them very carefully. 3. Place the bottom left and right logs as shown below in figure 28d. 4. Place the top left and right logs as shown in figure 28e. Base Log Bottom Right Log Bottom Left Log Figure 28d. Bottom left and right log placement.
H34D Gas Fireplace H34D Operation - Model H34D with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. ■ If you cannot reach your gas supplier, call the Fire Department. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas.
H34D Gas Fireplace Operation - Model H34D-I H34D-I with Honeywell Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition system that lights the pilot burner automatically. Do not attempt to light the pilot by hand. B. BEFORE LIGHTING smell all around the appliance area for gas.
H34D Gas Fireplace Operation Lighting Instructions See pages 14 and 15. Burner Adjustment The H34D is equipped with an adjustable burner, allowing you to raise or lower the flames. To adjust the flames, locate the black knob marked 'Hi-Lo', in the centre of the gas control valve (See Figure 29). The front burners are not adjustable. ■ To raise the flame height, turn the black knob (located behind the lower trim) counterclockwise. ■ To lower the flame height, turn clockwise.
H34D Gas Fireplace Maintenance Troubleshooting Gas Control Valve HONEYWELL SV 9500 /SV9600 Troubleshooting Sequence Power Generator Pilot Adjustment Screw NOTE: Before Troubleshooting, Familiarize Yourself With Wall Switch START The Startup And Checkout Procedure. INSET · Turn Gas Supply off · Set thermostat to call for heat Inlet Pressure Manifold Pressure Test Connection Spill Switch SV9500/SV9600 is powered (24 VAC nominal) NO Figure 30. Sit Nova 820 gas valve.
H34D Gas Fireplace Warranty The Warranty The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a tenyear warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control valve and fibre logs. Glass, plated/painted finishes, and refractory lining are exempt.
H34D Gas Fireplace Appendix A - Termination Locations A = clearance to the termination frame above grade, veranda, porch, deck, or balcony [16 inches (41 cm) minimum] B = clearance to door, or sides and top of window, that may be opened [16 inches (41 cm) minimum for appliances ≤100 000 BTU/H (30kW)] C = clearance to bottom of window that may be opened horizontally [36 inches (92 cm) minimum for appliances ≤100 000 BTU/H (30kW)] M = clearance to mechanical air supply inlet [*6 feet (1.
H34D Gas Fireplace Appendix B - H34D-MH Mobile Home Gas Control Valve This appliance may be installed as an OEM installation in a manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer's instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or The Mobile Home Standard, CAN / CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas indicated on the rating plate.
XG0130 Rev. 0 - 11/2003 Canadian Heating Products Inc. Montigo Del Ray Corp.