Owner`s manual


Page10
XG0649 - 031511






Connect all vent sections using a minimum of three sheet
metal screws on the outer pipe ue
E
nsure the pipe ends male to female slide in a minimum
of 1 1/2of overlap
Ensure all runs are supported with a minimum of 3 supports
per 10’ of venting
W
hen hanging/ supporting venting, ensure that 1” clearance
is maintained on all sides to any combustible material
Ensure when cutting sections of rigid pipe to maintain
integrity of internal supports
P
lace the springs, supplied with the pipe kit, between the
outer and inner pipes to keep the pipes separate and avoid
any possible hot spots
Montigo recommends the use of a ex section for the nal
pipe connected directly to the replace offering greater
exibility of installation and absorption of movement
A
ll exterior joints in venting should be sealed with high heat
silicone 706 High Temp
A - Termination EDVRSPV58
B - Rough-in Frame EDVRSPV58F
C - Flex Sections PLF-1 (12" Section)
PLF-2 (24" Section)
PFL-3 (36" Section)
PFL 4 (48" Section)
D - Rigid Sections PEXT-1 (12" m/f Section)
PXT-20 (20" Section)
PEXT-2 (24" m/f Section)
PEXT-3 (36" m/f Section)
PEXT-4 (48" m/f Section)
E - Elbows PEL-90MM (m/m 90º Elbow
PEL-90FF (f/f 90º Elbow
PEL-90FM (f/m 90º Elbow)
PEL-45FM (f/m 90º Elbow)
F - Power Cord
Harnesses
EPVH10-10 foot power cord & harness
EPVH20-20 foot power cord & harness
EPVH30-30 foot power cord & harness
EPVH40-40 foot power cord & harness
EPVH50-50 foot power cord & harness
EPVH60-60 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH80-80 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH80-80 foot power cord & harness
EPVH90-90 foot power cord & harness
EPVH100-100 foot power cord & harness
Installation of the EDVRSPV58 External roof mounted power vent
module.
Refer to Appendix A - Power Vent locations, to ensure the planned
Vertical Power vent location is acceptable
T
he EDVRSPV58F Rough-in Frame dimensions:
The EDVRSPV58 Power Vent dimensions:
Top View
Front View
Ø14”
8 1/2”
19 1/4”
Ø 1/2”
2”
18”
18”
Top View
Front View
Ø 8”
14”
6”
18”
18”