Owner`s manual
Page15
XG0649 - 031511
Figure 7. Framing the Opening for Power Vent
14 1/2”
14
1/2”
(Opening)
(Opening)
Step2.
Insert the Power Vent Rough-in Box as shown in Figure 7a
Fasten the Box securely in place with Screws or nails
Apply exterior
sheathing and nishing if required
Step3.
Next, remove the bottom collar and conduit mounting frame as
shown Figure 7b
(Place removed hardware in a handy location for
re-assembly)
F
igure 7a.
O
rientation, Placing the Power Vent Inner Box
Framing
Rough-in Frame
Fasteners
Figure 7b. Installation of Rough-in Kit
Installing the external wall mounted power vent module
Step1. Construct a frame for the termination opening to meet the
following requirements:
■ Opening Size must be: 14 1/2" x 14 1/2"
Figure 7c. Installation of Power Vent Conduit
Power Vent Conduit
Strain Relief
Nut
Step4.
Insert the conduit from the Power Vent Module into the rough-in
frame through the two top right entry holes
Remove the nut from the
supplied strain relief and place as shown, Figure 7c
Strain Relief
Figure 7d. (Installing Conduit connector & conduit mounting frame)
Power Vent Conduit
Strain Relief & tightened nut
Power Vent
Connector
Conduit
mounting
frame
Step5.
S
ecurely fasten bottom Collar pan into the Rough-in frame using
the existing hardware, (4-pcs)
Tighten Strain Relief nut onto Strain
relief
Step6.
P
ull Power Vent Connector, (from behind) half-way through
supplied hole in conduit mounting frame, and snap into place, (notches
in two plastic wing clips
Orientation not critical)
Tightened hardware, 4-pcs.
Step7.
Fasten Conduit mounting frame into place using existing hardware,
(6-pcs) (Coil conduit in behind cover)