Owner`s manual
Page17
XG0649 - 031511
InstallinganIn-LineLinearPowerVent(LDVPV58)
Thissectionappliestoinstallationswhereanexternalroof
or
wall
mounted
power
vent
is
not
aesthetically
acceptable
orfeasible.
VentingLayout
Selectionofcomponentsanddetailsofventinglayoutshould
adhere
tothefollowingguidelines:
Ensure there is a minimum run of 2’ of straight pipe between
the replace and the power vent
E
nsure the maximum vent run does not exceed 60'
Maximum vent run must be reduced by 10’ for 1’ of pipe
running in a vertical downward direction
E
nsure the number of 90º elbows does not exceed 3 (maximum
allowable vent run must be reduced by 10’ for every additional
90º elbow added)
Ensure the number of 45º elbows does not exceed 6
LinearPowerVent-HorizontalTermination
ExampleA. Vertical mounting with horizontal termination
** from fireplace to in-line power vent
Maximum allowable vent run must be reduced by ten feet (10'-0"
for every additional 90° elbow added With a snorkel Termination,
reduce the total vent run by an additional twenty feet (20'-0") Figure's
7 and 7a
F
igure
7
. Vertical Mounting for the Linear Power Venter
Figure 7a. Horizontal Vent for the Linear Power Venter.
ExampleB. Horizontal mounting with horizontal termination
** from fireplace to in-line power vent
Example
C
. Horizontal mounting with downward vent run and
horizontal termination
** from fireplace to in-line power vent
Maximum allowable vent run must be reduced by ten feet (10'-0")
for every additional 90° elbow added
Also, deduct ten feet (10'-0")
of vent length for every one foot (1'-0") of vent run traveling in a
downward direction
F
igure
7
b.
H
orizontaI Linear Power Vent with Downward vent
and Horizontal Vent Run to Termination.
CAUTION!
Vent terminations can be very hot. The termination is to be installed higher than 7 feet above a public walkway.
Do not obstruct, or attempt to conceal, the vent termination. These actions will aect the operation of the replace, and may be hazardous.
In heavy snow areas, take extra care to prevent snow buildup from obstructing the vent termination.
■ Vent terminations can be very hot. The
termination is to be installed higher than 7 feet
above a public walkway.
■ Do not obstruct, or attempt to conceal, the vent
termination. These actions will affect the operation
of the fireplace, and may be hazardous.
■ In heavy snow areas, take extra care to
prevent snow buildup from obstructing the vent
termination.
CAUTION
XW2026
VentingInstallation
Maximum
VentRun
Minimum
VentRun**
Max.#
Elbows
60 Feet 2 Feet 3
VentingInstallation
Maximum
VentRun
Minimum
VentRun**
Max.#
Elbows
60 Feet 20 Feet 3
VentingInstallation
Maximum
VentRun
Minimum
VentRun**
Max.#
Elbows
40 Feet 2 Feet 3
2’-0 ”
MIN
Vertical Installed
Linear Power Vent
Horizontal Run Flex Pipe
Vertical
Flex Pipe
90deg
Elbow
90deg
Elbow
90deg
Elbow
Termination
Snorkel
Termination
LDVPV58
Flush
Termination
VLWB-8
Option
Option
LDVPV58
Horizonta
l
Insta
ll
e
d
Linear Power Vent
Horizontal Run Flex Pipe
Vertical
Flex Pipe
90deg
Elbow
90deg
Elbow
90deg
Elbow
Termination
Snorkel
Termination
Flush
Termination
VLWB-8
Option
Option
Horizontal Installed
Linear Power Vent
Horizontal Run Flex Pipe
Vertical
Flex Pipe
90deg
Elbow
90deg
Elbow
Termination
6’-0”
Max.
LDVPV58