Owner`s manual
Page19
XG0649 - 031511
1 The linear power vent can be installed to existing stud
construction or directly to cement wall or roof TheLDVPV58
must maintain the clearance to combustibles as shown in Figure
9a The required service access panel must be framed at 28"
X 18" To enclose the service access panel, (at less than 2") a
minimum 30% free air must be supplied at all times
2
P
lug the power cord into the available slot in the linear power
vent
3 Secure all venting joints with at least three screws and ensure
that the joints are properly sealed by applying high temperature
silicone
F
igure
9 L
DVPV58 Power Vent overall dimensions.
Top View Side View
Figure
9
b
L
DVPV58 Power Vent framing dimensions.
FramingDimensions
Figure9a LDVPV58 Power Vent framing dimensions.
The VLWB-8 termination is
designed to be installed ush
with the exterior of the building
This recessed design uses 5"/8"
vent and allows the installation to
be clean and ush so it does not
interfere or have an impact with
your architectural design
N
OTE:
The H36PVN requires a specic volume of atmospheric interchange
to operate properly and efciently
The replace requires a MIN 80in/sq
air movement to function
The grille must also be able to shed water, not allowing any
moisture to enter the unit
Recessed Termination Installation (VLWB-8) Refer to Appendix A -
Termination locations
Figure10. Linear Power Vent recessed Termination.
13 5/16"
21 3/8"
18 1/8"
5
8
20 3/16"
12 9/64"
7 13/16"
2
1
ISOMETRIC VIEW
(NTS)
NTS
SIZE
DWG. NO.
A
REV.
SHEET 1 OF 1
WEIGHT:
VLWB-8
FINISH
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
1/32"
TWO PLACE DECIMAL
.015"
THREE PLACE DECIMAL
.005"
ALL BENDS ARE ASSUMED
TO BE 90
UNLESS NOTED
OTHERWISE.
CHECKED BY
DRAWN BY
LF
DATE
NAME
7/29/2010
304 S.S.T.
TERMINATION, VERTICAL MOUNT, 5/8", 12" X 20" BOX
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
Z:\CADD\2007 CADD\Standard\TERMINATIONS\VERTICAL TERMS\VLWB-8\VLWB-8
Thursday, July 29, 2010 10:14:21 AM
SCALE
Access Cover
16 1/2
33 8
11
34 7/8
Access Cover
181/2
28 clearance
for Cover access
5 MIN
5 MIN
Must be left clear on both
ends of Power Vent for
adequate ventilation.
2 MIN
5
MIN
5
MIN
1/2
MI
N
Louvres
Vent