Owner`s manual


Page24
XG0649 - 031511

Section6:InstallingtheGasLine
Figure 14. Gas line access. (See Figure 1,
L-H Side View)
 After gas line is connected, appliance connection
valve and valve train must be checked while under
normal operating pressure with either a liquid solution, or
leak detection device, to locate any source of leak. Tighten
any areas where bubbling appears or leak is detected until
bubbling stops completely or leak is no longer detected.
Gas line & valve: Exterior Access
The H36PVNis supplied one (1) one exterior access Panel (LH-side
rebox) This panel is fastened directly to the exterior of the rebox
with sheet metal screws To remove the panel follow the steps below:
Figure 15. (Removing the Gas valve
panel hardware).
Figure 15a. (Inset)
Figure 15b. (Incoming gas supply line (supplied by Montigo)
and top of Gas valve).
 




Gas Valve
Gas In, Figure 14
Exterior gas
access panel
hardware, 10-pcs.
10
4”
3”
Flexible Input
Gasline,
(Supplied)
Back of
Fireplace
FUELCONVERSION
V
erify that your replace is compatible with your available
gas type
(Natural Gas or Propane shown by "N" or "L" in
your model number
If gas type is not compatible, contact your local Montigo
representative to purchase a conversion kit
C
onversion kits must be installed by a qualied service
technician
GASPRESSURE
O
ptimum appliance performance requires proper input
pressures
Gas line sizing requirements will be determined in ANSI
Z2213 National Fuel Gas Code in the USA and CAN/CGA
B149 in Canada
P
ressure requirements are:
The manifold outlet pressure is set from the factory to the
appropriate pressure but should be veried
T
o check pressures, control valves have a provision to remove
a 1/8” N
P
T
plug to be tted with a hose barb
Montigo requires a service shut off valve be located in an
accessible location to isolate the gas supply
O
nly install gas shut-off valves approved for use by the state,
province, or other governing body in which the replace is
being installed
GASCONNECTION
S
ee Figure 22 below for location of gas line access
Flexible gas connectors must not exceed 3 feet in length,
unless allowable within local regulations
C
onnect incoming gas line to the 1/2"or 3/8" gas inlet port
Purge all air out of gas line
C
heck appliance connection, valve and valve train under
normal operating pressure with a commercially available
leak check solution
DO NOT USEA FLAME OFANY KINDTO TESTFOR
LEAKS.

GasPressure NaturalGas Propane
MinimumInletPressure 55" WC 11" WC
ManifoldPressure 35" WC 10" WC
When pressure testing the fireplace,
Gas line, and input system follow the
appropriate local codes or your area.
DO NOT connect the fireplace to
pressures in excess of 1/2lb. This will
damage the gas control valve.
NOTICE
XW2032