Owner`s manual


Page32
XG0649 - 031511

Removing the Interior rebox Access Panel:
The H36PVNis supplied one (1) one interior access Panel (LH-side
rebox) that contains the Gas valve, and electronics This panel is
fastened directly to the interior of the rebox with sheet metal screws
To remove the panel follow the steps below:
S
tep
1
.
R
emove the LH Refractory Panel as described in Figure 22
Step2.Remove the LH Refractory Stand-off Panel as described in
Figure 24 & 24a
S
tep
3
.
O
nce these two steps are complete, remove the eight (8)
machine screw that hold the Side panels in place, Figure 28
(P
hilips
head screwdriver required).
Step4.Slightly tilt panel, and pull out between the grate and rebox
wall, Figure 28a
Figure 28. (Removing the panel
hardware).
Figure 28a. (Removing the panel from
the rebox), incoming gas from service
and Gas valve.
Figure 28b. (Gas valve and Gas valve
electronic module). See figure 13a,
Schematic).
Figure 28c. (Gas valve electronic
module A/C Connection). See gure
13a, Schematic).
General
H
ave
t
he
replace
a
nd
i
nstallation
i
nspected
y
early
The
inspection must include, but is not limited to, the following:
• A visual check of the entire vent system and termination
A
n inspection of the explosion relief appers and the door
g
asketing to ensure a proper seal
An inspection of the burner, venturi, and primary air openings
• A
n inspection of the gas valve, gas components, and pilot
ame
For your convenience a 1/8" manifold pressure tap is
supplied on the gas valve for a test gauge connection
• Ensure proper log placement as per this manual
Inspection of all optional equipment; fans, thermostats, etc
For NaturalGas this appliance requires a minimum inlet pressure
of 55" WC and a manifold pressure of 35" WC
F
or Propane
G
as
t
his appliance requires a minimum inlet pressure
of 11" W
C
and a manifold pressure of 10" W
C
Always keep the replace area clear and free of combustible
materials, as well as gasoline and other ammable vapors and
liquids
D
o not use this appliance if any part has been under water
Immediately call a qualied service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water
C
leaning
When the replace is rst activated, there may be some smoking and
a visible lm may be left on the glassThis is a normal condition, and
is the result of burning of protective coatings on new metal
G
lass must be cleaned periodically to remove anylm (which is
a normal by-product of combustion) which may be visible
Film
can easily be removed by removing the door, as shown on Page
2
3
Handle the door carefully, and clean it with non-abrasive glass
cleaners
One of the most effective products is Kel Kem
Silicone seals on inner door during initial ring will "off gas", leaving
a visual deposit of a white substance on combustion chamber walls
This can easily be removed using normal household products
U
se a vacuum cleaner or whisk broom to keep the control
compartment, burner, and rebox free from dust and lint
Logs may be cleaned periodically with a vacuum to remove soot
or other contaminates
Grate
Access Panel
hardware,
7-pcs
Gas Valve, Control
Access Panel
Gas Valve
Gas Valve
Electronics
Gas valve
electronics
Blk Wht
Grate
Gas Valve