Installation & Maintenance Manual H38DF-CLCR HL38DF-CLCR HLS38DF-CLCR Corner Unit Residential Fireplace DANGER Read and understand this manual. Improper installation, adjustment, alteration, service or maintenance can cause serious injury, property damage or even death. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
H(L)38DF-CLCR Corner Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance. XW2010 Table of Contents INTRODUCTION ........................................................................3 Section 7: Removing the Door............................................18 BEFORE YOU START:.................................................................
H(L)38DF-CLCR Corner Gas Fireplace Safety Alert Key DANGER WARNING Indicates a hazardous situation which, if not avoided, WILL result in death or serious injury or property damage. Indicates a hazardous situation which, if not avoided, COULD result in death or serious injury or property damage. CAUTION NOTICE Indicates a hazardous situation which, if not avoided, WILL result in minor or moderate injury.
H(L)38DF-CLCR Corner Gas Fireplace Installation Section A: Before You Begin IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS The H*38C* Direct Vent fireplace must be installed in accordance with these Instructions. Carefully read all the Instructions in this manual first. Consult the Local Gas Branch to determine the need for a permit prior to starting the installation.
H(L)38DF-CLCR Corner Gas Fireplace Installation Section 1: Installation Overview and Product Dimensions Please review the Pre-Installation Checklist on Page 4 for general information on preparing for a successful installation of your fireplace. select a location that does not interfere with room traffic, has adequate ventilation and offers an accessible path for Direct Vent installation.
H(L)38DF-CLCR Corner Gas Fireplace Installation Section 2: Framing the Fireplace rame in the enclosure for the unit with framing materials. The framed opening for F the assembled fireplace is 48 " wide, 44 " high, 25 1/4" deep, see Figure 2. NOTICE NOTE: When constructing the framed opening, please ensure there is access to install the gas line when the unit is installed. See Figure 2. H38DF CL Corner Left Elbow must be installed directly off the back of the fireplace.
H(L)38DF-CLCR Corner Gas Fireplace Installation Section: 3 The Direct Vent System Montigo supplies a variety of direct venting and termination options. The direct vent termination location MUST be selected such that it is the highest point in the venting assembly. It should also be selected such that it provides the shortest vent run possible.
H(L)38DF-CLCR Corner Gas Fireplace Installation INSTALLING A ROOF MOUNTED DIRECT VENT TERMINATION PVTK1 Termination This section applies to installations where the direct vent termination will be roof mounted. 2’ min. Support ring VENTING LAYOUT Selection of components and details of venting lay out should adhere to the following guidelines: The maximum termination point is 32’ above the fireplace (NOTE: if the maximum termination height is used, the flame pattern may be affected).
H(L)38DF-CLCR Corner Gas Fireplace Installation Section: PVTK1 Termination Ensure when cutting sections of rigid pipe to maintain integrity of internal supports. Storm Collar Place the springs, supplied with the pipe kit, between the outer and inner pipes to keep the pipes separate and avoid any possible hot spots. Montigo recommends the use of a flex section for the final pipe connected directly to the fireplace offering greater flexibility of installation and absorption of movement.
H(L)38DF-CLCR Corner Gas Fireplace Installation (D). Installation of termination from inside structure INSTALLING A WALL MOUNT, DIRECT VENT TERMINATION A Termination with a MOSR Frame is installed from the inside of the structure. This section applies to installations where the direct vent termination will be wall mounted.
H(L)38DF-CLCR Corner Gas Fireplace Installation VENTING LAYOUT Acceptable vent run within non-shaded area. Selection of components and details of venting layout should adhere to the following guidelines: Vent terminations must not be recessed in walls or siding. All through-the–wall terminations within 58" Horizontal distance of the fireplace must have a Montigo Heat Shield (RHS102) installed. See Section 3-3-3.
H(L)38DF-CLCR Corner Gas Fireplace Installation Wall Mounted Terminations: Rear Vent PLEASE NOTE: REAR VENT APPLICATIONS MUST HAVE A 59" VERTICAL RISE. THEY CANNOT TERMINATE STRAIGHT THROUGH THE WALL, see figure 16. All dimension lengths for vertical or horizontal runs are measured from center of the vent pipe. Venting runs must fall within the limits set by the venting graphs, see Figure 16. Fireplace must be converted to Rear Vent configuration prior to running vent, see Figure 7 and 8.
H(L)38DF-CLCR Corner Gas Fireplace Installation Section: VENTING COMPONENTS The following components and associated Montigo part numbers are available for installation of a Wall Mounted Termination. Use only Montigo Vent Components. Use of non-Montigo parts will void the warranty and may impede operation of the fireplace.
H(L)38DF-CLCR Corner Gas Fireplace Installation Heat Shields Installing a Wall Mounted RHS101 Heat shield. Installing a Wall Mounted RHS102 Heat shield. The RHS102 where the termination is closer to the fireplace than 58" horizontally. To install the RHS102, Slide the Inner Section over the vent pipe that will connect to the fireplace. Then fasten the vent pipe to the back of the fireplace with a minimum of three sheet metal screws. From the outside slide the RHS102 outer section on see Figure 19.
H(L)38DF-CLCR Corner Gas Fireplace Installation Section 4: Wiring Honeywell (Q3450) Pilot Assembly WARNING Pilot Electrical Harness Connector Honeywell Gas Control (SV9501M) If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. XW2008 Gas Control Connector Fan Plug Receptacle Junction Box Black White Green 115VAC 24VAC Gnd Screw 40 VA Transformer Wall Switch Figure 20.
H(L)38DF-CLCR Corner Gas Fireplace Installation Section 5: Installing the Gas Line FUEL CONVERSION Verify that your fireplace is compatible with your available gas type. (Natural Gas or Propane shown by "N" or "L" in your model number If gas type is not compatible, contact your local Montigo representative to purchase a conversion kit. Conversion kits must be installed by a qualified service technician.
H(L)38DF-CLCR Corner Gas Fireplace Installation Section 6: Finishing Mantels & Surrounds Finishing Around the Fireplace Combustible mantels and mouldings may be safely installed over the top and on the front of the fireplace provided that they do not project beyond shaded area shown in Figure 24.
H(L)38DF-CLCR Corner Gas Fireplace Installation Section 7: Removing the Door Removing the Front door: The H*38C* Front door is removed in a few simple steps. Follow these below to remove the Horizontal access panel, unlatch the door buckles and, remove the door. Replace in reverse order. The smaller Side door is bolted in place. Remove the Horizontal Access Panel: Step 1: Remove the Horizontal cover by placing fingers in both finger holes, then pushing away from you and lifting out.
H(L)38DF-CLCR Corner Gas Fireplace Installation Section 8: Installing the Accessories Installing the Logset The H*38C* is supplied with eight (8) fibre logs. The two small bottom logs ("A" ) are mounted on the burner grate by placing them diagonally onto the supplied Log stands. The long Front / Back logs ("B") are placed against the grate as shown in Figure 27c. Note: When placing logs, arrange Logs "B" as not to cover Burner holes.
H(L)38DF-CLCR Corner Gas Fireplace Installation Installing Firestones in N.G. (Natural Gas) Fireplaces Installing Firestones in L.P. (Propane) Fireplaces The H*38C* is supplied with firestones. Remove the Door and trim as shown in the previous Instruction. Follow these instructions to ensure all parts are removed or replaced as required. Once the glass door is removed place the firestones randomly across the pan and the burners as described in Figure 28 to 28b.
H(L)38DF-CLCR Corner Gas Fireplace Operation Section 9: Lighting WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
H(L)38DF-CLCR Corner Gas Fireplace Operation SIT Nova 820 with American Electronic Ignition For Your SafetyFlame - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. XW2008 Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. A. This appliance has a pilot which must be lighted by hand.
H(L)38DF-CLCR Corner Gas Fireplace Operation Honeywell For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. XW2008 A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas.
H(L)38DF-CLCR Corner Gas Fireplace Operation Robert Shaw For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. XW2008 A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas.
H(L)38DF-CLCR Corner Gas Fireplace Maintenance Section 10: Cleaning and Maintenance Lighting Instructions See pages 21 - 24 Hi-Lo Burner Adjustment: (SIT Nova 820). General Have the fireplace and installation inspected yearly. The inspection must include, but is not limited to, the following: A visual check of the entire vent system and termination. An inspection of the explosion relief flappers and the door gaskets to ensure a proper seal.
H(L)38DF-CLCR Corner Gas Fireplace Maintenance Section 11: Replacement Parts MODEL# H38C* H38C*I HL38C*I NG Gas Valve RGC1006 RGC3033 RGC3033 LG Gas Valve RGC1005 RGC3034 RGC3034 NG Pilot RPA020 RPA033 RPA033 LP Pilot RPA021 RPA034 RPA034 Burner Assembly NG RBH38PR01 RBH38PR19 RBHL38PR19 Burner Assembly LPG RBH38PR02 RBH38PR20 RBHL38PR20 Logs RLGS47PR RLGS47PR N/A Page 26 XG0213 - 020111
H(L)38DF-CLCR Corner Gas Fireplace Appendix Appendix A: Power Vent Locations V Horizontal Detail Vertical Detail A = clearance to the termination frame above grade, veranda, porch, deck, or balcony [30 inches (75 cm) minimum] N = † clearance above paved sidewalk or a paved driveway located on public property [*7 feet (2.1 m) minimum] B = clearance to door, or sides and top of window, that may be opened [30 inches (75 cm) minimum for appliances.
H(L)38DF-CLCR Corner Gas Fireplace Appendix Appendix B: Warranty The Warranty The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo fireplace, there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control valve, fibre logs and Power Vent Module.