H*38DF-PFC* Indoor Gas Fireplace
Part No. XG0816 - 100210
Installation Checklist
Determine the desired install location of your replace.
See Section 1, Dimensions on Page 5, and refer to the Framing
Section 2 for details.
Select the location of your termination and resulting vent run.
Your selected termination location must be the highest point
in the Direct Vent installation.
Should it be impossible to meet the venting requirements laid
out in Section 3: Venting, please contact Montigo regarding the
use of a Montigo Power Vent.
Lay out the Vent run; calculating the required elbows and straight
runs of 5"/8" flex or rigid pipe.
Layout Electrical Requirements Refer to Section 4: Wiring, for
Details.
Refer to Section 5: Installing the Gas Line, for details on the
gas connection and access.
Refer to local codes and guidelines for installation requirements.
Installation and repairs should be done by a qualied
contractor and must conform to:
Installations in Canada must conform to the current
CAN/CGA B-149.1 and .2 Gas Installation Code and local regulations.
Installations in the USA must conform to local codes,
or in the absence of local codes to the National Fuel Gas Code, ANSI
Z223.1-1988
.
See Appendix C for installation within the State of
Massachusetts. This replace must comply with NFPA-54 Chapter
10.
Installation
WARNING!
When this appliance is installed directly on any combustible
material other than wood ooring, it must be installed on a
metal or wood panel extending the full width and depth of
the appliance.
IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS
The H*38PF* Direct Vent replace must be installed in
accordance with these Instructions. Carefully read all the
Instructions in this manual rst. Consult the Local Gas Branch to
determine the need for a permit prior to starting the installation.
It is the responsibility of the installer to ensure this replace is
installed in compliance with the manufacturers instructions and
all applicable codes.
BEFORE YOU START:
INSTALLATION AND REPAIRS SHOULD BE DONE
BY AN AUTHORIZED SERVICE TECHNICIAN. THE
APPLIANCE SHOULD BE INSPECTED BEFORE USE
AND AT LEAST ANNUALLY BY A PROFESSIONAL
SERVICE TECHNICIAN. MORE FREQUENT CLEANING
MAY BE REQUIRED DUE TO EXCESSIVE LINT
FROM CARPETING, BEDDING MATERIAL, ETC. IT
IS IMPERATIVE THAT CONTROL COMPARTMENTS,
BURNERS AND CIRCULATING AIR PASSAGEWAYS
OF THE FIREPLACE ARE KEPT CLEAN.
CAUTION!
Due to its high operating temperatures, the appliance should
be located out of trafc & away from furniture and draperies.
Children and adults should be alerted to the hazards
of the high surface temperature, which could cause
burns or clothing ignition.
Young children should be carefully supervised when
they are in the same room as the appliance.
Clothing or other ammable materials should not be
placed on or near the appliance.