Owner`s manual

Page 7
H*38DF-PFC* Indoor Gas Fireplace
Part No. XG0816 - 100210
4”
4”
Clearances
When installing a shelf over the top of the replaces, the following
guidelines must be adhered to:
For Rear Vent applications, the minimum clearance is 2" from the rear of
the replace to a wall, or any combustible materials, and 11" clearance
from the top of the replace to the underside of any combutible shelf
materials.
For Top Vent applications, the minimum clearance is 2" from the rear of
the replace to a wall, or any combustible materials, and 17 1/2" to the
underside of any combutible shelf materials.
(Minimum 2" clearance must still be maintained around all horizontal
vent pipes.)
MODEL
Top - Rear vent
*
Top - Top vent
Back
Sides
Floor
Mantel
H*38PF* 11" 17 1/2" 2" 1" 0" 4"
Installation
Figure 7. Installing the Nailing Flange Extension.
Installing The Standoffs
To avoid elevated mantel temperatures, all H*38PF*-Series gas
replaces are required to have the supplied standoffs installed.
The replace is supplied with two standoffs. Bend and install these
standoffs on top of the replace ensuring that the height of the standoff
maintains a 4" clearance.
Figure 6. Installing the standoff's.
The Nailing Flange Extension
The supplied 4" nailing extension must be placed along the top edge
of the replace and securely fastened in place with the supplied
hardware. Note: The nailing ange extension may be substituted with
a piece of NON-Combustible material of the same thermal character-
istics, ie: cement board or equivilent to t the opening. This is recom-
mended in applications where the facing materials will not adhere to
the metal nailing ange.