Owner`s manual

H*38DF ST Indoor Gas Fireplace
Page 27
XG0207 - 011012.1
Maintenance
Troubleshooting
SIT Nova 820
The following is a troubleshooting chart of possible problems:
PROBLEM CORRECTIVE ACTION
Noisy Pilot Flame Locate pilot adjustment screw on
gas control valve. Flame is decreased by
turning adjustment screw clockwise.
Pilot won’t ignite Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram gure
28.
Main burner will 1. Check wiring (see gure 28).
not light 2. Check wall switch for proper
connection.
Honeywell
The following is a troubleshooting chart of possible problems:
If your replace still does not operate correctly, consult your local Montigo dealer.
All service and repairs should be performed by a qualied Technician.
All spare parts, optional fans, and optional trim nishes are available from your local Montigo dealer.
SIT Proame
The following is a troubleshooting chart of possible problems:
PROBLEM SOLUTION
Pilot won't ignite or spark. - Check the on the batteries on the
remote or the receiver.
- Check the green LED on AC adaptor
-Check the green ground wire under
the valve
Main burner will not light. - Check the wiring on the valve as per
diagram Figure 17.
Fan not working - Make sure the fan speed control is on.
- 10 minute delay to turn on.