Installation Operation & Maintenance H52-DFN Gas Fireplace Safety Notice: Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain hot even after the fireplace has been turned off. Safety screens are available and can reduce the risks of severe burns. Please keep children away from the fireplace at all times. Check local codes and read all instructions prior to installation.
H52-DF Gas Fireplace Warning: Read this manual before installing, operating or troubleshooting this appliance. Please retain this owner's manual for future reference. Congratulations Congratulations on selecting a Montigo gas fireplace, an elagent and well designed gas fireplace built to your specifications. The Montigo gas fireplace you have selected is designed to provide the utmost in safety, reliability, and engineering standards.
H52-DF Gas Fireplace Introduction Thank You for choosing a Montigo Gas Fireplace. About this Fireplace: The H52-DFN is a fireplace with a pan-style burner and glowing embers. This fireplace is ONLY available as a Top Vent, natural gas fireplace. The H52-DFN is rated for Natural Gas at 60,000 BTU/H (17.65 Kilowatts) Input. Available in Intermittent Pilot (HSI), NG Models Top Vent Only. How to use this manual: This manual covers installation, operation and maintenance.
H52-DF Gas Fireplace Installation Installing The Fireplace Shell Framing N The fireplace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumbing. Safety, as well as efficiency of operation, must be considered when selecting the fireplace location. Try to select a location that does not interfere with room traffic, has adequate ventilation, and offers an accessible pathway for Direct Vent installation.
H52-DF Gas Fireplace Installation Note: After gas line is connected, each appliance connection, valve and valve train must be checked while under normal operating pressure with either a liquid solution, or leak detection device, to locate any source of leak. Tighten any areas where bubbling appears or leak is detected until bubbling stops completely or leak is no longer detected. DO NOT use a flame of any kind to test for leaks.
H52-DF Gas Fireplace Installation Installing Heat Guards over Terminations Installing The Power Vent The LDVPV58 Linear Power Vent System must ONLY be used with a Montigo H52-DFN Direct Vent Fireplace. When selecting Venting components for use with this Linear Power Vent System, take into consideration the various requirements and limitations in the vent installation section of the Model's manual: Models Must Be Equipped with Electronic Ignition (HSI/AF) PTKOG (5"/8") 1.
H52-DF Gas Fireplace Installation Specifications: Important: Ensure prior to vent installation, the 4-hole 5"/8" flue adapter is installed on the exhaust vent of your Montigo H52-DF gas fireplaces (Part No. H52C-A03B). Dimensions: 34 7/8"L x 18 1/2"W. x 11 1/2"D. Vent Size: (IN) 5"/8" (Out) 5"/8" Motors: 1/10HP each, x 1.8A each (2) motors Sound Level: dba Weight: 60Lbs.
H52-DF Gas Fireplace Installation Linear Power Vent - Horizontal / Downward Vent WARNING: All venting material must be sealed with high heat silicone sealant RV230. All venting material to be Montigo flex pipe, with as few joints as possible. All joints use MVA vent splice, sealed thoroughly with silicone. WARNING: Multi-elbow installations are possible up to a maximum seventy feet (70'-0"), with three (3) 90° elbows. Minimum vent run from Fireplace to Power Vent must be two feet, (2'-0").
H52-DF Gas Fireplace Installation Example B. Vertical Mounting with Vertical Vent Run Framing Dimensions Termination 2’-0” MIN 5 MIN 90deg Elbow 90deg Elbow 5 MIN 181/2 90deg Elbow 28 clearance for Cover access Vertical Installed Linear Power Vent LDVPV58 90deg Elbow Vertical Flex Pipe Access Cover Important: Maximum Vent Run not to exceed Seventy (70’-0”) feet. Must be left clear on both ends of Power Vent for adequate ventilation. 1/2 MIN Figure 8b.
H52-DF Gas Fireplace Installation Installing The Horizontal & Vertical Exterior Power Vent Restrictor Ring Installation (H52DFN ONLY) Vertical, Exterior Stainless Steel Roof top Power Vent, (see Instruction guide for), EDVRSPV47/58 Restrictor Ring Part No EPVR55. Figure 14. EPVR55 for H52DF Only Restrictor Ring Installation. (From inside firebox ONLY) Figure 11a. Vertical, Exterior Stainless Steel Roof top Power Vent, Horizontal.
H52-DF Gas Fireplace Installation BX Conduit Main Junction Box F Receptical F To 115V AC Supply M2 W W W Bk Bk L2 M1 Bk L1 W Transformer Power Vent TDR W Bk Fuse Air Proving Switch R 24V 115V G R Strain Relief TDR Coil Bl Wall Switch Bk Bl Legend Fireplace W Strain Relief Bk Denotes Line Voltage Denotes Low Voltage Denotes Wire Connector Air Switch R Gas Control Connector Figure 12. Wiring schematic for the Post Purge Control Module ECB006.
H52-DF Gas Fireplace Installation Installing the Log Set Mantels & Surrounds NOTE: National Canadian Gas Association mantel test requirements are for fire hazard prevention to combustible materials. New technology, to meet consumer and government demands for the wise use of energy, has prompted us to manufacture many models of fireplaces which are hot, fuel and energy efficient. Installing the Logs: The H52-DFN is supplied with seven ceramic fibre logs.
H52-DF Gas Fireplace Installation Removing and Installing the Doors Log G Log A Log F Removing the doors: The doors are removed in a few simple steps. Follow the Steps shown to remove the Horizontal access panel, unlatch the door buckles, remove the door, then replace in reverse order. Remove the Horizontal Access Panel: Step 1: Log Grate Figure 16c. Installation of Log G. Step 4. Place Log "G" in place on the provided flat areas (plateau's) as shown. See Figure 16b.
H52-DF Gas Fireplace Installation WARNING! Do not attempt to clean glass when hot. Step 4 L42DF-ST Do not clean glass with abrasive materials as any glass etching may cause premature glass failure. Ensure the tool is firmly in the lower end of the slot, (as shown), Then pull toward you (Caution: hold the tool securely). 2 Figure 28d. Step 5 Pull hard if necessary to release the spring tension. (Caution: The latch springs back with force, hold the tool securely). 3 Figure 28e.
H52-DF Gas Fireplace Operation - Model H52-DF-I with Honeywell Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition system that lights the pilot burner automatically. Do not attempt to light the pilot by hand. B. BEFORE LIGHTING smell all around the appliance area for gas.
H52-DF Gas Fireplace Maintenance General Troubleshooting ■ Have the fireplace and installation inspected yearly. The inspection must include, but is not limited to, the following: HONEYWELL SV9500 /9600 Troublshooting Sequence • A visual check of the entire vent system and termination. • An inspection of the explosion relief flappers and the door gasketing to ensure a proper seal.
H52-DF Gas Fireplace Warranty The Warranty The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control valve and fibre logs. Glass, plated/painted finishes, and refractory lining are exempt.
H52-DF Gas Fireplace Appendix A - Termination Locations A = clearance to the termination frame above grade, veranda, porch, deck, or balcony [16 inches (41 cm) minimum] N= B = clearance to door, or sides and top of window, that may be opened [16 inches (41 cm) minimum for appliances ≤100 000 BTU/H (30kW)] P = clearance under veranda, porch, deck, or balcony [16 inches (41 cm) minimum‡ to non-combustibles] [22 inches (56 cm) minimum‡ to combustibles] clearance above paved sidewalk or a paved driveway l
H52-DF Gas Fireplace Appendix A - State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.
XG0650 - 120108 Canadian Heating Products Inc. Montigo Del Ray Corp.