H52-DF Gas Fireplace
Part No. XG0650
Specications:
Dimensions: 34 7/8"L x 18 1/2"W. x 11 1/2"D.
Vent Size: (IN) 5"/8" (Out) 5"/8"
Motors: 1/10HP each, x 1.8A each (2) motors
Sound Level: dba
Weight: 60Lbs.
Installation
CAUTION:
When cold air enters the warmer building interior, primarily at the
air intake end, condensation may occur on the exterior of the ex
pipe. To limit this condensation, install insulation over the last
twenty feet of ex pipe. Also, by sloping the last 20'-0" feet of ex
pipe downward toward the exterior of the building, elimination of
most of the condensation problems should occur. Ensure the ter-
mination is securely fastened, and sealed to the ex pipe. Fasten
the termination to exterior of the building with water tight sealant
and the appropriate fasteners.
CAUTION:
Ensure the Perforated Air Holes in the Factory Installed
Pipe Adapter / Restrictor are not Covered when installing
New Pipe Connection.
Venting Installation
The LDVPV58's Power Vent must be installed with the H52-DFN gas
replace equipped with an electronic ignition system. When installing the
venting, the installation must adhere to the Venting Installation Section
in this Installation Operation and Maintenance Instructions, as well as
these few following guidelines:
Ensure that the planned termination location is acceptable as
shown in Appendix A.
Minimum of 2 feet of straight pipe before the power vent.
Important: Ensure prior to vent installation, the 4-hole 5"/8" flue
adapter is installed on the exhaust vent of your Montigo
H52-DF gas fireplaces (Part No. H52C-A03B).
Figure 6. Illustration diagram for the LDVPV58 Linear Power Venter
M
LDVP58 Power Vent
PTO3,
DPV58
Termination
Exhaust
Intake
Fireplace
110VAC
Not Switched
Post Purge
Wall
Switch
Hot Service Igniter
Electronic Ignition Gas Control
Exterior Wall
Remote wiring to
Power Vent from
Post Purge Control
H52C-A03B