Owner`s manual

H42DF Series Indoor Gas Fireplace
Part No. XG0148 - 012810
Page 14
Installation
Finishing Around the Fireplace
Combustible mantels and mouldings may be safely installed over the
topandonthefrontofthereplaceprovidedthattheydonotproject
beyond shaded area shown in Figure 24.Sidewallclearancesare3".
Combustiblesurroundsmaybeinstalledwith3"clearancetotheside
ofthereplaceasshowninFigure 25.
Figure 25. Combustible surrounds.
Wiring
Gas Control and Pilot Wiring
H42DF-I
Figure. 26. Wiring for the H42DF-I with Honeywell gas control and pilot.
Figure 24. Combustible mantles and facings.
Fireplace Facing
Whenselectingthenishmaterialforyourreplace,itisimportantto
remember the following:
Ifthesurroundofthereplaceistobepaintedtomatchtheroomdecor,
heat-resistant paint must be provided . Also, decorative facing must not
extendpastthereplaceopeningatall,becauseitwillinterferewiththe
access to retainers for removal of glass door and access to the lower
compartment.
Horizontal Run (in)
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Junction Box
115VAC
24VAC
40 VA
Transformer
Black
White
Green
Gnd Screw
Wall Switch
Fan Plug
Receptacle
Facing Material
Header
Drywall/
Sheetrock
Painting:
Special care is recommended by the Master Painters and Decorators
Association,whenpaintingthereplacesurrounds,toselectandapply
a quality Alkyd sealer prior to the applying of latex paints. This is to
prevent leaching of water from evaporation and causing a brownish
staining effect to paint over coats.
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
areforrehazardpreventiontocombustiblematerials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
replaceswhicharehot,fuelandenergyefcient.
Pleasebeaware;temperaturesoverthemantelwillriseabovenormal
roomtemperatureandwallsabovereplacemaybehottotouch.
Warning:
When covering the upper metal portion of the replace with a non-
combustible material Please Note: The decorative facing materials
may be subject to temperatures in excess of 250° F. This should be
considered when selecting facing materials.
We recommend careful consideration be given to the effects of elevated
mantel temperatures which may be in excess of product design, for
example: candles, plastic or pictures. This can cause melting, deformation,
discoloration or premature failure of T.V. and radio components.