Owner`s manual
Page 3
H42DF Series Indoor Gas Fireplace
Part No. XG0148 - 012810
Introduction
CAUTION!
Due to its high operating temperatures, the appliance
should be located out of traffic & away from furniture and
draperies.
Children and adults should be alerted to the hazards
of the high surface temperature, which could cause
burns or clothing ignition.
Young children should be carefully supervised when
they are in the same room as the appliance.
Clothing or other flammable materials should not be
placed on or near the appliance.
WARNING!
When this appliance is installed directly on carpeting, tile or any
combustiblematerialotherthanwoodooring,itmustbeinstalled
on a metal or wood panel extending the full width and depth of
the appliance.
Thank You for choosing a Montigo Gas Fireplace.
About this Fireplace:
The H42DF-Series is an line of replace's with a standard LogSet,
also Linear-style burner, or Stainless steel, and Premium model. These
replacescanbeconvertedtobothaTopVentorRearVentapplication,
andareavailableinthespecicmodelsbelow.
The H42DF is rated for Natural Gas and Liquid Propane at 34,000 Max.
BTU/H (9.97) Kilowatts, 25.000 Min. BTU/H Input.
► H42DF; Top or Rear Vent convertible, Millivolt Pilot
► H42DF-I; Top or Rear Vent convertible, Intermittent Pilot (HSI)
The HL42DF is rated for Natural Gas and Liquid Propane at 32,000 Max.
BTU/H (9.97) Kilowatts, 21,000 Min. BTU/H Input.
► HL42DF-F; Top or Rear Vent convertible, (Electronic HSI IPI).
The HR42DF is rated for Natural Gas and Liquid Propane at 34,000 Max.
BTU/H (9.97) Kilowatts, 25.000 Min. BTU/H Input.
► HR42DF; Top or Rear Vent convertible, Millivolt Pilot
► HR42DF-F; Top or Rear Vent convertible, (Electronic HSI IPI).
This manual covers installation, operation and maintenance. Lighting,
operation and care of thisreplacecanbeeasily performed by the
homeowner. However, all installation and service work should be
performedbyaqualiedorlicensedinstaller,plumber,orgastterwho
isqualiedorlicensedbythestate,province,region,orgoverningbody
in which the appliance is being installed.
This manual covers all models and unless otherwise specied, the
designation H42DF refers to all variations of the model above. Sections
whicharespecictoaparticularvariationaremarkedwitha
symbol, plus the appropriate model number.
Warranty and Installation Information:
The Montigo warranty will be voided by, and Montigo disclaims any
responsibility for, the following actions:
► Modication of the replace and/or components including Direct-Vent
assembly or glass doors.
►UseofanycomponentpartnotmanufacturedorapprovedbyMontigoin
combinationwiththisMontigoreplacesystem.
►Installationotherthanasinstructedinthismanual.
Consult your local Gas Inspection Branch on installation requirements
forfactory-builtgasreplaces.Installation&repairsshouldbedoneby
aqualiedcontractor.
Installations in Canada must conform to the current CAN/CGA B-149.1
and .2 Gas Installation Code and local regulations. If the optional air-
circulating fan kit is installed, it must be electrically grounded in accordance
with CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes.
Installations in the USA must conform to local codes, or in the absence
of local codes to the National Fuel Gas Code, ANSI Z223.1-1988. If the
optional air-circulating fan is installed, it must be grounded in accordance
with local codes or, in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70-1987. See Appendix for installation
within the State of Massachusetts. Thisreplacemustcomplywith
NFPA-54 Chapter 10.