Installation
Installing Terminations with Built-In Frames
Installing Terminations with MSR Frames
12
12
1. Frametheterminationopeningto12"x12".
2. Fasten the termination to the studs using a minimum of 4 screws.
11
11
1. Frametheterminationopeningto11"x11".
2. Fasten the termination to the studs using a minimum of 4
screws.
Installing Terminations with MOSR Frames
1212
12
MOSR
1. Frametheterminationopeningto12"x12".
2. FastentheMOSRframetotheinteriorsideofthestudsusinga
minimum of 4 screws.
3. InserttheterminationintotheMOSRframeasshownhere,and
attach by screwing through the four pilot holes in the termination.
MSR
PTO-3F (5"/8")
PTO (5"/8")
PTO-4F (5"/8")
PTO-3F (5"/8")
MTKOG (4"/7")
PTKOG (5"/8")
1. Ensure that the two long mounting brackets are facing the bottom
of the termination. (See inset). This will provide more heat protection
at the top of the termination, where temperatures are highest.
2. Attach to the faceplate of the termination using four sheet metal
screws.
Installing Heat Guards over Terminations
Installing The Standoffs
To avoid elevated mantel temperatures, all H42DF Series gas
replaces are required to have the supplied standoffs installed.
The replaceissupplied with two standoffs.Bend and install these
standoffsontopofthereplaceensuringthattheheightofthestandoff
maintainsa6"clearance.
Figure 6b. Installing the standoff's.
Figure 4a. Installing a PTO termination.
Figure 4b. Installing a PTO termination with the MSR frame.
Figure 4c. Installing a PTO termination with the MOSR frame.
Figure 4d. Installing a PTO termination heat guard.
Figure 6c. Installing the Nailing Flange Extension.
steel lintel is in place, (Part No. L42087) (see Figure 2), the supplied
nailingextensionmustbeplacedalongthetopedgeofthereplace
and securely fastened in place to the metal lintel, and combustible
woodframing.Note:Thenailingangeextensioncanbesubstituted
withapieceofNON-Combustiblematerialofthesamesizeand
thermal characteristics, ie: cement board or equivilent.