Owner`s manual

Page 9
H42DF Series Indoor Gas Fireplace
Part No. XG0148 - 012810
Installation
PEL
RHS8 Heat Shield
Figure 10. Typical Top Vent installation. If the 90° elbow is installed
directly on the replace, for height to the center of the
termination see chart on page 3.
PEL-90F/F Elbow
Horizontal Venting
Figure 11. Typical Top Vent installation. The solid sections can be used
in various combinations to obtain the desired vent run. The
vent run must fall within the limits set by the venting graph.
Figure 12. Extended Installation using a combination of solid and ex
venting. Use the vent graph to determine your allowable
run, then select appropriate components.
90° Elbow
PEXT Section
Termination
Example 2:
Rigidsectionsandanelbowusedinconjunctionwith3ft.exsection
(PFL-3)will,whenextendedinavefootchase,allowforamaximum
horizontalrunoftwelveandone-halffeetfromthecentreofthereplace
tooutsidewallandaminimumof7'6"whenretractedinoppositedirection
(see Figure 12 and 13).
"C"exsectionsand"D"rigidsectionsmaybeusedinconjunctionwith
one another to obtain different possible horizontal length installations.
NOTE: Flex section with no vertical rise must not exceed maximum
horizontal length of 3 feet (see Figure 14). Flex runs over 3 feet must
fall within the limits set by the venting graph, and must have a minimum
verticalriseof3"perfootofex.
RHS8 Heat
Sheild
RHS8 Heat
Shield
Figure 13. Retracted Installation using a combination of solid and ex
venting. Use the vent graph to determine your allowable
run, then select appropriate components.
Figure 14. Horizontal ex installation with no vertical rise.
RHS8 Heat
Shield
RHS8 Heat
Shield
42” Max.
45”
Min.