HW42DF Gas Fireplace
Part No. XG0191 - 031010
Installation
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
areforrehazardpreventiontocombustiblematerials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
replaceswhicharehot,fuelandenergyefcient.
Please be aware; temperatures over the mantel will rise above normal
roomtemperatureandwallsabovereplacemaybehottotouch.
Figure 25. Combustible surrounds.
Wiring
Non-Combustible
Facing Material
Header
Drywall/
Sheetrock
6”
Wiring for the optional Fan Kit
All HW42DF replaces may be equipped with optional fan kits for
circulating heat into the living space.
Installations in Canada which employ the fans must be electrically
grounded in accordance with CSA C22.1 Canadian Electrical Code
Part 1 and/or Local Codes.
Installations in the USA which employ the fans must be grounded in
accordance with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70-1987.
For more information see the Fan Kit Installation Guide included with
the fan kit.
NOTE: If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.
Figure 27a. Wiring schematic for optional fans.
G
L2-WH
L1-BLK
p g
Quick Connect
lu to motor
5/1/60 Supply
G L1 L2
Finishing Around the Fireplace
Combustible mantels and mouldings may be safely installed over the
topandonthefrontofthereplaceprovidedthattheydonotproject
beyond shaded area shown in Figure 24.Sidewallclearancesare3".
Combustiblesurroundsmaybeinstalledwith3"clearancetotheside
ofthereplaceasshowninFigure 25.
Fireplace Facing
Whenselectingthenishmaterialforyourreplace,itisimportantto
remember the following:
Ifthesurroundofthereplaceistobepaintedtomatchtheroomdecor,
heat-resistant paint must be provided . Also, decorative facing must not
extendpastthereplaceopeningatall,becauseitwillinterferewiththe
access to retainers for removal of glass door and access to the lower
compartment.
Non-Combustible
Facing Material
Figure 24. Combustible mantles and facings.
Horizontal Run (in)
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
areforrehazardpreventiontocombustiblematerials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
replaceswhicharehot,fuelandenergyefcient.
Please be aware; temperatures over the mantel will rise above normal
roomtemperatureandwallsabovereplacemaybehottotouch.
Warning:
Whencoveringtheuppermetalportionofthereplace,upto6"(as
shown, Fig.24 & Fig.25) with a non-combustible material Please Note:
The decorative facing materials may be subject to temperatures in excess
of 250° F. This should be considered when selecting facing materials.
We recommend careful consideration be given to the effects of elevated
mantel temperatures which may be in excess of product design, for
example: candles, plastic or pictures. This can cause melting, deformation,
discoloration or premature failure of T.V. and radio components.