Owner`s manual
Page 8
HW42DF Gas Fireplace
Part No. XG0191 - 031010
B
C
A
42” NG
45”
36
5/8 NG
PEL
Installation
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 66" and the horizontal run to
the wall flange of the vent termination is 60", this would be an acceptable
installation.
Example B: (Acceptable Installation)
If the vertical dimension from the hearth is 108" and the horizontal run to
the wall flange of the vent termination is 172", this would be an acceptable
installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 60" and the
horizontal run to the wall flange of the vent termination is 144", this would
NOT be an acceptable installation.
NOTES: All dimension lengths for vertical or horizontal runs are
measured from centre of the vent pipe.
Venting runs must fall within the limits set by the venting
graph (see Figure 7).
Available Top Vent Components
The following venting components are available for he HW42DF Top Vent.
Example 1:
ForourshortestventingcongurationusecomponentsAandE(see
Figure 10).
Figure 10. Typical Top Vent installation. If the 90° elbow is installed
directly on the replace, for height to the center of the
termination see chart on page 3.
Horizontal Venting
Figure 11. Typical Top Vent installation. The solid sections can be used in
various combinations to obtain the desired vent run. The vent
run must fall within the limits set by the venting graph.
90° Elbow
PEXT Section
Termination
Example 2:
Rigidsectionsandanelbowusedinconjunctionwith3ft.exsection
(PFL-3)will,whenextendedinavefootchase,allowforamaximum
horizontalrunoftwelveandone-halffeetfromthecentreofthereplace
tooutsidewallandaminimumof7'6"whenretractedinoppositedirection
(see Figure 12 and 13).
"C"exsectionsand"D"rigidsectionsmaybeusedinconjunctionwith
one another to obtain different possible horizontal length installations.
NOTE: Flex section with no vertical rise must not exceed maximum
horizontal length of 3 feet (see Figure 14). Flex runs over 3 feet must
fall within the limits set by the venting graph, and must have a minimum
verticalriseof3"perfootofex.
Figure 9b. HW42DF Top Vent Venting Graph
PowerVentmodels,EDVRR&EDVRW
to be used within the shaded area of
graph.(SeeBELOWforapplicable
Product information).
5" / 8" Venting
A - TerminationP TO-3(3"Length)
PTO-3F(3"Length)
B - Stucco Kits MSR (Stucco Frame)
MOSR(StuccoCan)
BSR ( Brick Can)
C - Flex Sections PFL-1(12"Section)
PFL-2(24"Section)
PFL-3(36"Section)
PFL-4(48"Section)
D - Rigid
Sections
PEXT-1(12"m/fSection)
PEXT-2(24"m/fSection)
PEXT-3(36"m/fSection)
PEXT-4(48"m/fSection)
E - Elbows PEL-90MM (m/m 90° Elbow)
PEL-90FF (f/f 90° Elbow)
PEL-90FM (f/m 90° Elbow)