Owner`s manual

Page 6
L38DF-ST* Indoor Gas Fireplace
Part No. XG0810 - 081310-1
Section 2: Framing
Installation
1). Frame in the enclosure for the unit with framing materials. The
framed opening for the assembled replace is 41" wide, x 40" high
x 23 3/4" deep, see Figure 2
.
NOTE: When constructing the framed opening, please ensure
there is access to install the gas line when the unit is installed.
See Figure 22.
Figure 2. Framing dimensions.
Clearances
When installing a shelf over the top of the replaces, the following
guidelines must be adhered to:
For Rear Vent applications, the minimum clearance is 3" from the rear of
the replace to a wall, or any combustible materials, and 10" clearance
from the top of the replace to the underside of any combutible shelf
materials.
For Top Vent applications, the minimum clearance is 3" from the rear of
the replace to a wall, or any combustible materials, and 17 1/2" to the
underside of any combutible shelf materials.
Figure 2a. Framing dimensions, (Back-framing)
Figure 4. Combustible Framing for shelves over the replace, Top
vent.
Figure 3. Combustible Framing for shelves over the replace, Rear
vent.
40”
41”
23 3/4”
40”
34 1/2”
Both walls Typical. May
not be exactly as shown.
Notes:
Install supplied metal header (Part
No#L38ST060) above replace after
unit is in place. Use supplied hardware
to fasten to framing. Both sides Typi-
cal. Unit may not be exactly as shown.
Backframe Min. 37 3/4”
Figure 5. Non Combustible Framing with alcove above replace,
Right side. Combustible Framing above replace, Left side, see
gure 2. (Top Vent).
Non
Combustible
Header
7”
Floor
Alcove over
Fireplace Non
-
Combustible
Materials Only
34 1/2”
29 1/2”
door
opening
40”
7”
Combustible
Header
Min. 1”
Supplied
Header
10”
Top vent
N.G. & L.P
10”
Min.
Supplied shield
Combustible Shelf
N.G. & L.P
26 3/4
12” Max.
3” Min.
39 1/2” Min.
17 1/2”
Min.
PEL Short
90 elbow
Supplied shield
Combustible Shelf
N.G. & L.P
3” Min.
L38DF-ST 10" 17 1/2" 3" 1" 0" 4"
MODEL
Top - Rear Vent *
Top - Top Vent
Back
Sides
Floor
Mantel