Owner`s manual

Page 19
L52DF-ST* Indoor Gas Fireplace
Part No. XG0811 -100511
To Turn Off Gas To Appliance:
1. Turn off remote switch.
2. Remove the lower Horizontal access panel.
3. Turn the incoming gas control valve to "Off".
4. Replace the lower Horizontal access panel.
with American Flame Electronic Ignition
For Your Safety - READ BEFORE LIGHTING:
Proame SIT Electronic Ignition
Lighting Instructions:
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the Fire
Department.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or turn by hand,
don't try to repair it, call a qualied service technician. Force or at-
tempt to repair may result in a re or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualied service technician to inspect the
appliance and to replace any part of the control system, and any gas
control which has been under water.
A. This appliance is equipped with an ignition system that
lights the pilot burner automatically. Do not attempt to light the pilot by
hand.
B. BEFORE LIGHTING smell all around the appliance
area for gas. Be sure to smell next to the oor because some gas is
heavier than air and will settle on the oor.
What To Do If You Smell Gas:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbour's
1. STOP! Read the safety information above on this label.
2. Remove the lower Horizontal access panel.
3. Turn Incoming gas valve to the ON" position.
4. Wait 5 minutes to clear out any gas. If you smell gas, STOP!
Follow "B" in the safety information above on this label. If you
don't smell gas, go to the next step.
5. Turn wall switch "ON".
6. If the Fireplace does not light, the System will cycle through
two trials, (one minute audible clicking, thirty seconds of
silence, and then another one minute of audible clicking).
7. After completion of the information in the Troubleshooting
section, Repeat step 5.
8. If the system will not function correctly, follow the instructions
"To Turn Off Gas To Appliance" and call your service techni-
cian or gas supplier.
EV1 (Pilot
burner)
EV2 (Main
burner)
Pilot Adjust Screw
Lockout Reset Key
Diagnostic Terminal
Power
Command (Wall
switch)
Pilot Sensor
Igniter
Ground
EV1 (Pilot burner)
EV2 (Main burner)
Gas "Out"
Gas "In"
Incoming Gas
Line, Shut-off
Valve
To replace Main
burner
Models
L52DFNI
L52DFLI
If the information in these instructions is not followed exactly, a fire or explosion may
result causing property damage, personal injury or death.
WARNING
Operation