Owner`s manual

Page 21
L52DF-ST* Indoor Gas Fireplace
Part No. XG0811 -100511
Troubleshooting: (Honeywell).
If your replace still does not operate correctly, consult your dealer or
the manufacturer.
All service and repairs should be performed by a qualied
Technician.
All spare parts, optional fans, and optional trim nishes are available
from your local dealer or the manufacturer.
Models Included
L52FSDN
L52FSDL
Models Included
L52FSDNE
L52FSDLE
Maintenance
Troubleshooting SIT Nova 820
The following is a troubleshooting chart of possible problems:
PROBLEM CORRECTIVE ACTION
Noisy Pilot Flame Locate pilot adjustment screw on
gas control valve. Flame is decreased by
turning adjustment screw clockwise.
Pilot won’t ignite Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram gure 33.
Main burner will 1. Check wiring (see gure 33).
not light 2. Check wall switch for proper con-
nection.
Troubleshooting: (IPI System).
The following is a troubleshooting chart of possible problems:
PROBLEM SOLUTION
Pilot won't ignite or spark. - Check the on the batteries on the
remote or the reciever.
- Check the green LED on AC adaptor
-Check the green ground wire under
the valve
Main Burner Will not light - Check the wiring diagram on the
valve as per diagram seen in Figure
20a
Fan not working - Make sure the fan speed control is
on.
- 10 minute delay to turn on.
Models Included
L52FSDNI