Instruction manual

Section 4-1-3: Installation of the Vertical External
Roof Mounted Power Vent Module
Refer to AppendixA-PowerVentlocations, to ensure the planned
Vertical Power vent location is acceptable.
See PowerVentmanual for installation instructions.
Section 4-1-2: Venting Components
The following venting components and associated Montigo part
numbers are available for the appliance:
Connection and installation of the vent components should
adheretothefollowingguidelines:
Connect all vent sections using a minimum of three sheet
metal screws on the outer pipe ue.
Ensure the pipe ends male to female slide in a minimum
of 1 1/2“ of overlap.
Ensure all horizontal runs are supported with a minimum
of 3 supports per 10’ of venting.
When hanging/ supporting venting, ensure that 1” clearance
is maintained on all sides to any combustible material.
Ensure when cutting sections of rigid pipe to maintain
integrity of internal supports.
Place the springs, supplied with the pipe kit, between the
outer and inner pipes to keep the pipes separate and avoid
any possible hot spots.
Montigo recommends the use of a ex section for the nal
pipe connected directly to the replace offering greater
exibility of installation and absorption of movement.
All exterior joints in venting should be sealed with high heat
silicone RV230.
A - Termination PV VEX510-300
B - Rough-in Frame Supplied with PVVEX510-300
C - Flex Sections RLF-1 (12" Section)
RLF-2 (24" Section)
RFL-3 (36" Section)
RFL 4 (48" Section)
D - Rigid Sections REXT-1 (12" m/f Section)
RXT-20 (20" Section)
REXT-2 (24" m/f Section)
REXT-3 (36" m/f Section)
REXT-4 (48" m/f Section)
E - Elbows REL-90MM (m/m 90º Elbow
REL-90FF (f/f 90º Elbow
REL-90FM (f/m 90º Elbow)
REL-45FM (f/m 90º Elbow)
F - Power Cord
Harnesses
EPVH10-10 foot power cord & harness
EPVH20-20 foot power cord & harness
EPVH30-30 foot power cord & harness
EPVH40-40 foot power cord & harness
EPVH50-50 foot power cord & harness
EPVH60-60 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH80-80 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH80-80 foot power cord & harness
EPVH90-90 foot power cord & harness
EPVH100-100 foot power cord & harness
R520-ST & R620-ST Power Vent Indoor Gas Fireplace
Page 13
XG0773 - 150127
Installation