Installation & Maintenance Manual PVHFL58-300 & PVHFL510-300 5/8 and 5/10 Horizontal Flush Louvered Power Vent WARNING NOTICE PVHEX510-300 power vent is approved for use with Montigo R520, R520-ST, R620-ST, R720, and R820. If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. NOTICE PVHEX58-300 power vent is approved for use with Montigo R320, R320-ST, R420, R420-ST, and RP620.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Safety Alert Key Introduction Specifications Pipe Dimensions PVHFL58-300 . ........... 5"/8" Pipe Dimensions PVHFL510-300 . ......... 5"/10" Maximum Airflow: .......................... 300 CFM Speed: ........................................... 2700 RPM Power:............................................. Connect to fireplace control box . ...........................................
1 " 4 311 12 1 " 4 311 12 1 21 " 1 8 21 " 8 Dimensions Product 538 538 3 " 4 476 18 PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Introduction 3 " 4 476 18 2" 50 1 " 4 565 22 5 1 22 " 24 8 " 4 565 627 2" 50 5 " 8 627 24 5 " 8 421 Front View 16 5 " 8 421 16 Side View PVHEX10-300 10" 254 PVHEX58-300 8" 203 Back Cover / Collar Outer Assembly 5" 126 1 " 4 311 12 Inner Assembly 1 " 8 538 21 Louver Assembly Top View Figure Step 1 1.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Installation Installing the power vent Step 2: Remove the louver assembly by lifting the bottom end forward and then dropping the door out of the top latches. 3 " 4 476 18 Framing Outer Can Assembly 1 " 4 565 22 Figure 3a. Wall Board Step 3: To remove the inner can from the outer can remove the 8 screws on the back of the termination. Figure 2. Framing dimensions Step 1: Unpack power vent from box. Remove two screws from bottom of the door.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Installation Step 4: Slide the inner can out by pulling Step 6: Slide the inner can assembly into the outer can assembly from the inside of the house. Structure Outer Can Assembly Inner Can Assembly Power Cord from Power Vent All framing shown is combustible Figure 3e. Step 7: Screw inner can back to outer can using 8 screws. Figure 3c. Step 5: Screw outer can assembly into the wall 3 " 4 476 18 Framing Outer Can Assembly 1 " 4 565 22 Figure 3f.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Installation Step 8: Remove two screws securing electrical plate. Step 11: Attach the power cable from the power vent to the control cable. Figure 3j. Step 12: Push all the excess cable back into the electrical channel of the power vent. Screw the electrical plate back on the power vent. Figure 3g. Step 9: Remove the power vent power cable from inside the electrical channel. Figure 3j. Figure 3h.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Installation Step 13: Reinstall the door. Tabs Front Grill into the Out Can y by inserting top tabs into the ame and securing the bottom with s provided. Louver Assembly Screw Locations Figure 3l. Step 14: Connect vent pipe to power vent collar as required. Note: If you are intending to service power vent from inside the house, use a 4-foot flex pipe to allow for easy removal of pipe from power vent.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Service Power Vent Wiring 6 PIN MOLEX CONNECTOR GREEN BLUE BLACK BROWN C BLACK WHITE KEY WAY Figure 4a.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Installation PVHEX58 300 E INSID ETAIL ER D CORN G v H A D E V B FIXED ED CLOS v V L B B C FIXED ED CLOS ABLE OPER v E F ABL OPER v A I M X v X v B v K J B V VENTER TERMINAL Canadian Installations X AIR SUPPLY INLET 1 US Installations 2 A= Clearance above grade, veranda, porch, deck, or balcony 12 in (30 cm) 12 in (30 cm) B= Clearance to window or door that may be opened 6 in (15 cm) for appliances < 10,000 Btuh (3 kW)
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Service Servicing From the outside of the house Step 4: Remove the three screws securing the rain guard. Step 1: Turn off gas and power. Step 2: Remove two screws from the bottom of the louver assembly. Caution: Hold the louver assembly securely so it does not fall. Figure 5. Step 3: Remove the louver assembly by lifting the bottom end forward and then dropping the door out of the top latches. Figure 5b.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Service Reinstalling from the outside Step 1: Reinstall the rain guard using the supplied 3 screws. Figure 6. Step 2: Reinstall door with supplied 2 screws. Tabs Front Grill into the Out Can y by inserting top tabs into the me and securing the bottom with provided. Louver Assembly Screw Locations Figure 6a.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Service Servicing From the inside of the house ing (from inside) Step 1: Turn off gas and power. Step 2: Disconnect venting from the power vent Step 5: Remove 8 screws securing the inner can assembly to the outer can assembly. ng he . Venting Vent Termination Figure 7. ing Step 3: Remove two screws securing the electrical plate. Figure 7c. Step 6: Slide the inner can out by pulling. Place the inner can assembly somewhere to work.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Service Step 7: Remove the three screws securing the rain guard. Figure 7e. Go to Capacitor or Motor and Capacitor Replacement Section.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Service Reinstalling the inner can From the inside of the house Step 3: Secure inner can to the outer can with supplied 8 screws. Step 1: Screw the rain guard back on with the supplied 3 screws. Figure 8b. Step 4: Plug control cable back into power vent power cable. Figure 8. Step 2: Slide the inner can into the outer can Figure 8c. Step 5: Stuff excess wire back into electrical channel and secure electrical plate with supplied two screws.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Service Capacitor Replacement REC 1250 Note: Maintenance must be preformed by qualified personnel/ electrician Step 3: Cut fibre white wire from power cable, black wire from capacitor and black wire from motor. Figure 9. Step 1: Cut the two zap straps securing the wiring. Figure 9c. Step 4: Unscrew mounting screw securing capacitor and remove capacitor. Figure 9a. Figure 9d. Step 2: Cut the brown wire from the motor. Step 5: Strip all wire ends.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Service Step 6: Using the large bell connector, connect the black fibre wire from the power cable to the black wire from the motor and the black wire from the capacitor. Figure 9f. Step 7: Using the small bell connector, connect the brown wire from the motor to the black wire from the capacitor. Step 8: Secure the wiring neatly with the supplied zap straps. Check that the power vent operates and spins counterclockwise.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Service Motor and Capacitor Replacement REC 1251 Note: Maintenance must be preformed by qualified personnel/ electrician Figure 10. Step 1: Cut the two zap straps securing the wiring. Step 3: Cut fibre white wire from power cable, black wire from capacitor and black wire from motor. Figure 10c. Step 4: Cut the black fiber wire from the power cable. Figure 10a. Step 2: Cut the brown wire from the motor. Figure 10d.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Service Step 6: Unscrew 8 screws securing the motor mounting plate. Step 9: Secure motor mounting plate with supplied 8 screws & star washers. Figure 10f. Figure 10i. Step 7: Remove the motor. Step 10: Secure new capacitor with supplied screw. Figure 10j. Step 11: Using suppled small bell connector, connect the blue wire from the motor to the black fibre wire from the power cable. Figure 10g. Step 8: Install the new motor. Figure 10k. Figure 10h.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Service Step 12: Using the other supplied large bell connector, connect the white fibre wire from the power cable to the black wire from the capacitor and the black wire from the motor. Go to reinstalling either from outside or inside. Figure 10l. Step 13: Using the other supplied small bell connector, connect the brown wire from the motor to the black wire of the capacitor. Figure 10m. Step 14: Secure the wiring neatly with the supplied zap straps.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Appendix Appendix A: Warranty The Warranty The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo fireplace, there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control valve, fibre logs and Power Vent Module.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent Appendix Appendix B: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.
PVHFL58-300 & PVHFL510-300 Power Vent Termination Ferndale, Washington TF: 1.800.789.6236 FX: 1.866.3000.0927 XG0519 - 070714 Langley, British Columbia TF: 1.800.378.3115 FX: 1.604.607.