Installation
Step 9.
Install the Power Vent. Place the Power Vent into the Rough-in
frame, aligning the Power Vent into nal position. Ensure the
Harness is placed down in the Rough-in box when placing the
Power Vent. (Secure the Power Vent in Place with the supplied
hardware).
Figure 5f. (Installation of Power Vent communication harness)
TOP of Power Vent,
(Note Quantity of
louvers).
Note louver
direction
Tightened hard-
ware,
4-pcs.
Communication
Harness.
Converting to Top Vent / Rear
Vent
All C-View Residential are boxed and shipped as Top Vent replaces.
Should your installation specications require that you install your Vent
system on the Rear of the replace, read the following instructions carefuly.
1. Remove the eight machine screws that secure the 10" cover plate
to the rear vent take off location of the replace. (Ensure you do
not damage the bre gasket)
2. Then, carefuly Remove the 5" cover plate that is installed on the
inner rear vent take off location. (Ensure you do not damage the
bre gasket).
3. Now, remove the Top vent (5" inner and 8" or 10" outer) ue Collars.
Switch the Collars and Cover plates as shown in, Figure 10.
Figure 10. Flue cap installation, Top Vented replace.
Converting the Pressure Sensing
tube from Top vent to Rear vent
All C-View Residential are shipped as Top Vent replaces. The
replace will have installed a formed pressure sensing tube. This tube
which is installed at the factory is maufactured of 1/4" aluminum tubing,
Figure 11. It will be required to remove the pre-installed 1/4" tube and
Replace with the supplied Rear vent tube / part as described below.
Aim the pressure sensing tubing (Top Vent or Rear Vent) as shown in
Figure 11 to activate the control System. (Oval below)
Top Vent
Opening
Rear Vent Opening
Fitting installed
inside replace
Pressure sensing
tube, (Top Vent
conguration when
shipped). Replace
with the part for Rear
vent conguration.
Replace tube from top vent congu-
ration with Part supplied with the
replace for rear vent conguration.
Figure 11. Fireplace Air Proving switch, tubing conguration.
CAUTION!
When installing the Rear vent pressure sense tube, aim into the
rear vent opening the same way as pictured in this installation,
Figure 11. A loose tting of the are nut will result in a malfunc-
tioning or problematic replace installation.
Flare Nut on (Top
& Rear, pressure
sensing tubing, (do
not overtighten).
Figure 5g. (Completed Installation of Power Vent)
Testing the System
The C-View Residential Control and Power Vent System can be
safely tested prior to nish framing the Fireplace. This test can be
done quickly and efciently to ensure all systems function according
to the design specications.
The replace should be installed on the rough-in frame, Figure 6a
with the Power Vent Module and the Vent Termination connected.
5” Inner Flue Collar, Typ.
10” Outer Flue Collar, R520,
R620 (with gasket)
10” Flue Cover Plate, Typ.
R520, R620 (with gasket)
5” Flue Cover Plate, Typ.
All models (with gasket)
All models (with gasket)