Owner`s manual
Page 13
C-View Residential R520-R620 Series Indoor Gas Fireplace
Part No. XG0771 - 070111
f i r e f e a t u r e
Framing for the Residential
replace:
Instructions for framing the platform and enclosure are covered in the
following Pages. To ensure the replace ts as shown in the Speci-
cations please read all the instructions.
Frame the rough-in opening for the replace as per the framing
instruction with the measurements provided in Figure 6. After you
frame the enclosure to these measurements install the metal header
across the top of the replace opening. Install the cement board
provided with the replace ,or replace it with a larger non-combustible
board should you nd this to your advantage. The bottom of the
replace may be framed with combustible materials as long as you
maintain the clearances required. Install drywall or any other combus-
tible board to the the front face of the framing, however no not cover
the area where the cement board is installed. You may cover this por-
tion with alkaline paint or any non-combustible materials for the area
that is designated in Figure 18.
Recessing the replace into the Floor:
You may recess this replace into the oor to meet your design
parameter. Make sure that the gas connection has been taken into
consideration. Maintain the clearances on the back of the replace
the same way as if you would frame this unit.
Building a low Prole Enclosure:
Maintain the clearances to the top the sides and the back of the
replace as per the installation instruction / Clearance specica-
tions. Should these clearances not suit your design a cement board
enclosure may be an alternative. Keep in mind that the exterior of the
enclosure will get hot and decorative items may be damaged.
Note: minimum clearances will directly translate into elevated tem-
peratures and will still get hot, and decorative items placed near the
replace may be damaged.
Installation
1 3/4”
2 1/4”
1/2” gas
inlet
Figure 14. Gas Inlet Supply location, (Right-hand side of replace).
Installing The Gas Line
The gas connection is located on the right side of the lower portion
of the replace body. The manufacturer requires a service shut off
valve located in an accessible location to isolate the gas supply. The
gas line must be installed, and tested for leaks before nishing the
CView Residential Fireplace. Natural Gas requires a minimum inlet
gas supply pressure of 5.5" W.C. & a manifold pressure of 3.5" W.C.
Propane requires a minimum inlet gas supply pressure of 11" W.C.
& a manifold pressure of 10" W.C. The manifold outlet pressure is set
from the factory to the appropriate pressure and should be veried.
The manufacturer has provided an inlet pressure tap location in the
replace for easy access. The control valves have a provision to
remove a 1/8 plug so that a hose barb tting can be installed to check
pressure.
Note: After gas line is connected, each appliance connection,
valve and valve train must be checked while under normal
operating pressure with either a liquid solution, or leak
detection device, to locate any source of leak. Tighten any
areas where bubbling appears or leak is detected until
bubbling stops completely or leak is no longer detected.
DO NOT use a ame of any kind to test for leaks.
WARNING!
When pressure testing the replace, Gas line, and input system
follow the appropriate local codes or your area. DO NOT connect
the replace to pressures in excess of 1/2lb. This will damage
the gas control valve.
110V Power Supply
LED Indicator
Fuse
Figure 12. 110V Power Supply Figure 12a. (Fuse & LED Indicator)
Ignitor
Operation
Lights
Figure 12b. (LED Igniter Indicators)
If the red LED is illuminated (beside the fuse) you have power to
the panel.
The power vent motor should start running and time out after
three to four minutes.
Turn the wall switch to the on position.
Observe the two LED on the right side of the panel. If both LED
are lilluminated and the hot service igniters are glowing red, it is work-
ing correctly.
Note: No gas is needed to prove the system.
The control panel is supplied with a power cord plug in.
Plug it into a extension cord or any other 110 Volt power supply.