Owner`s manual

Page 19
C-View Residential R520-R620 Series Indoor Gas Fireplace
Part No. XG0771 - 070111
f i r e f e a t u r e
Operation
WARNING! If you do not follow these instructions exactly, a re or
explosion may result causing property damage, personal injury or loss of life.
Startup Sequence:
A. Purge all air out of the gas supply line to the replace sys-
tem and ensure that the supply pressure is not in excess of
12" WC.
B. Plug the electrical control panel into the power outlet. (The
power vent will start and run for about three minutes and
then turn off.
Caution: Do not turn OFF the power to this panel at this
time to operate the replace
1. Turn the speed control on the right side of the panel to a low
positing ( clockwise ).
2. Turn the wall switch to the "On" position. The LED on the
left of the panel should illuminate.
3. Turn the speed up on the speed control knob very slowly
until the right LED is illuminated. Note: There will be a 1/2
minute Time-On delay, then burner will re up. This Initial
setting will produce the most attractive looking re. How-
ever, You may increase the speed if desired.
4. If the right LED is not illuminated when the power vent
module is running it will be a signal that the combustion air
supply is inadequate.
For Your Safety - READ BEFORE LIGHTING:
in your building.
Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the Fire De-
partment.
C. Do not use this appliance if any part has been under water.
Immediately call a qualied service technician to inspect the
appliance and to replace any part of the control system, and
any gas control which has been under water.
A. This appliance is equipped with an ignition system that
lights the pilot burner automatically. Do not attempt to light
the pilot by hand.
B. BEFORE LIGHTING smell all around the appliance area for
gas. Be sure to smell next to the oor because some gas is
heavier than air and will settle on the oor.
What To Do If You Smell Gas:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone
WARNING! If you do not follow these instructions exactly, a re or
explosion may result causing property damage, personal injury or loss of life.
Operation: With Honeywell Intermittent Pilot
This replace has been set up at the factory for a determined air volume though the venting system.
This replace will not operate unless the correct air movement is detected by our control system..
Please consulted with your contact person at Montigo should you have any problems with your start up.
CAUTION!