C-View Residential R520-R620 Series Indoor Gas Fireplace
Part No. XG0771 - 0070111
f i r e f e a t u r e
Installation
Top View
Vertical Power Vent
Requirements
It is recommended that the External Power Vent System be used with
a gas replace that is equipped with HSI. When installing the venting,
the installation must adhere to the Vent Installation Section in the re-
place's Installation Operation and Maintenance Instructions, as well
as the following guidelines:
The EPVRR Power Vent dimensions are show below.
Front View
The Vertical EPVRR
Power Vent
Installation Requirements for Vertical Power Venter
The C-View Residential Series replace use a Designated coaxial vent
system designed specically for the Residential replace, and Use of other
non-certied parts will void the Montigo warranty, and may impede the opera-
tion of the replace.
Ensure that the planned termination location is acceptable as shown
in Appendix A.
■ Maximum allowed vent run is 100 feet. (Refer to Montigo Reference
Document, XG1035) for all Possible variations not described here.
Vertical runs must be supported by a minimum of three supports per 10 feet
of venting.
For vertical installations the longest vent run is 140 feet with a limit of 6
-90° Elbows, or 12 - 45° Elbows. For longer runs contact the C-View
Manufacturer.
It is important that the location of the power vent motor is not exposed to a
downfall of water not in excess of the standard rain fall.
The Vertical EPVRRF
Power Vent Rough-in Frame
Installation Requirements for Vertical Power Venter Rough-
in Frame.
The C-View Residential Series replace use a Designated coaxial vent
system designed specically for the Residential replace, and Use of other
non-certied parts will void the Montigo warranty, and may impede the opera-
tion of the replace.