Owner`s manual
Page 7
C-View Residential R520-R620 Series Indoor Gas Fireplace
Part No. XG0771 - 070111
f i r e f e a t u r e
Installation
Installing the Vertical EPVRR
Power Vent
Figure 4. Contruction, Rough-in framing.
Step 1. Construct a Vertical Chase for the termination opening to
meet the following requirements:
■ Opening Size must be: 14 1/2" x 14 1/2" x 18" Min. height.
■ Maximum allowed vent run is 100 feet. (Refer to Montigo
Reference Document, XG1036) for all Possible variations not
described here.
Step 2.
Install the Vent pipe female end up, and 2" to 3" MAX. from
the top of the Constructed Chase. Also, at this point install the
Electrical harness, (EPVH-(10-100) that will communicate with
the Power Vent Module.
Vent Pipe
Vent Chase
Electrical Harness
with Connection
2 to 3” M
AX
Figure 4a. Installation, Vertical Vent pipe. (female end top end).
Hang the vent components from the ceiling or the wall and maintain
1" clearance around all vent pipe to any combustible materials. When
using Montigo ex pipe or rigid elbows ensure that the inner pipe is
fastened with three metal screws as well as the outer pipe.
Place the springs, supplied with the pipe kit, around the inner pipe
before installing the outer pipe over the inner. This will separate the
two pipe and avoid any possible hot spots.
Available EPVRR Vertical
Vent Components
Selecting A Termination Location
Before installing the termination or venting, check to ensure the
planned termination location is acceptable and meets basic require-
ments shown in Appendix A ( Termination Locations).
Installing the Residential’s Terminations with Frame
1. Frame the termination opening for replace models, R520 and
R620, Pages 6 and 7.
2. Fasten the termination and its frame in place using a minimum of
4 screws, installation below.
The following venting components are available for the C520 and
C620 Top Vent.
Connecting the Venting
Connect the vent system with a Montigo Flex section to the replace
pipe for ease of installation. Flex pipe sections are made in 24"
lengths, model RFL-2, through to model RFL-4, 48" long). When
installing these vent components fasten each section with a minimum
of three sheet metal screws on the outer and inner ue pipes.
Rigid Vent components are made in 12" sections, model REXT-1
through to model REXT-5, 60" long. Make sure that these inner pipes
are connected securely, and slide into each other to a minimum of
1 1/2". Review and compare your vent run to the information in the
Exterior Power Vent Installation Section..
5" / 10" Venting
A - Termination EPVRR
C - Flex Sections RFL-1 (12" Section)
RFL-2 (24" Section)
RFL-3 (36" Section)
RFL-4 (48" Section)
D - Rigid Sections REXT-1 (12" m/f Section)
REXT-2 (24" m/f Section)
REXT-3 (36" m/f Section)
REXT-4 (48" m/f Section)
E - Support Ring
& Plate
RSPXT-10
F - Firestop RS-10
B - Rough-in Frame
EPVRRF
14 1/2”
14 1/2”
1 ”8