Specifications
The following components and associated Montigo part numbers are for
installation of a roof or wall mounted Power Vent.
Use of non-Montigo parts will the warranty and may impede
operation of the replace.
º
º
º
º
Connection and installation of the vent components should
adhere to the following guidelines:
Montigo recommends the use of a ex section for the nal pipe
connected directly to the replace offering greater exibility
of installation and absorption of movement.
F
irestops must be installed as required by National & local
codes.
Montigo recommends that all exterior corners and joints be
sealed with exterior caulking. However, we encourage you
to consult your Building Envelope Engineer or Waterproong
Consultant for further recommendations.
U
se any combination of rigid and ex pipe as required and in
any orientation (Male connectors can face in any direction).
Flex sections may be stretched up to 50% of their total length
(e.g. a 24” section maybe stretched to 36”).
E
nsure the pipe ends male to female slide in a minimum of
1 1/2” of overlap.
Connect all vent sections using a minimum of three sheet
metal screws on the outer pipe ue.
E
nsure all runs are supported with a minimum of 3 supports
per 10’ of venting.
When hanging/ supporting venting, ensure that 1” clearance
is maintained on sides and bottom of vent runs and 2” above
horizontal vent runs to any combustible material.
R
igid pipe may be cut less than half way from the female
end only.
Ensure when cutting sections of rigid pipe to maintain integrity
of internal supports.
P
lace the springs, supplied with the pipe kit, between the
outer and inner pipes to keep the pipes separate and avoid
any possible hot spots.
IMPORTANT:
Please Refer to your Building Envelope
Engineer or Waterproong Consultant
for a review of ALL penetrations through
exterior walls or the roof.
Page 23
XG0771 - 040513
Section 3-4: Venting components