Specifications

Service
Page 11
XG0518 - 070714
Figure 5h.
Step 8: Using the large bell connector, connect the white ber wire
from the power cable to the black wire from the motor and the black
wire from the capacitor.
Figure 5i.
Step 9: Using the small bell connector, connect the brown wire from
the motor to the black wire from the capacitor.
Figure 5g.
Step 7: Strip all the wires for connection. Using old ground screw
secure the ground wire and new capacitor to the motor.
Figure 5f.
Step 6: Remove ground screw that secures the ground wire and
capacitor bracket to the motor. Note: Keep this screw for later use.
Dispose of old capacitor.
PVHEX58-300 & PVHEX510-300 Horizontal Power Vent