User Manual

31
LFO KEYBOARD TRACKING AMOUNT
To specify how much the LFO rate tracks the keyboard
pitch, enter Shift mode and press the BANK 2 and
PATCH 4 buttons. Pressing the low C key sets keyboard
tracking to zero, meaning key pitch will have no effect
on LFO rate. Pressing higher keys sets a proportionally
greater amount of keyboard tracking; the middle C
on the keyboard sets 1:1 LFO pitch tracking, meaning
the LFO rate will double when the key pitch doubles.
The high C key sets 2:1 LFO pitch tracking, meaning
that the LFO rate will change by four times for every
octave of pitch change.
LFO MIDI SYNC
This lets you synchronize the Subsequent 25 LFO with
an external MIDI clock signal, typically from another
synth, a sequencer, or a digital audio workstation.
When synced, the LFO rate locks to tempo, oscillating
in rhythm with its clock source. The LFO RATE knob
lets you select the note division—whether the LFO
cycles once every eighth note, half note, or whatever.
LFO MIDI sync is turned on by default. Engage Shift
mode and press the BANK 2, PATCH 3, and PATCH 4
buttons. Press the low C# key to turn on LFO MIDI sync,
and press the C key to turn it off. At the LFO RATE
knob’s fully counterclockwise position, a single LFO
cycle is 4 whole notes long (384 MIDI clocks). At its
fully clockwise position, one cycle equals a 1/64th-note
triplet (1 MIDI clock). Please refer to the chart on
page 42 for a list of clock divisions for LFO sync.
NOTE: When no clock is present, the LFO will run freely at a
rate determined by its RATE setting.
FILTER ENVELOPE
FILTER ENVELOPE TRIGGER MODE
As mentioned in the Envelopes Overview, by default,
legato playing on the Subsequent 25 keyboard prevents
Envelopes from retriggering on subsequent notes. With
single triggering, Subsequent 25 prevents Envelopes
from retriggering on subsequent notes unless you’ve
released the previous key. With multiple triggering,
a new Gate occurs each time you play a note on the
keyboard, regardless of whether you’ve released the
previous key. You can select single or multiple triggering
separately for the Amplifier and Filter Envelopes.
To specify single or multiple triggering for the Filter
Envelope, engage Shift mode and press the BANK 3
and PATCH 1 buttons. Press the low C key to select
single triggering, and press the low C# key to select
multiple triggering.
Single Trigger
Multi Trigger
Consistent LFO Rate
LFO KB Tracking Amt +
LFO MIDI Sync OFF
LFO MIDI Sync ON
HIDDEN PARAMETERS (Continued)