Specifications
SECTION 3: WIRING AND INSTALLATION T200 User's Manual
PAGE 3-73
3.15.3  General Purpose Description of the Analog Inputs
The T200 has two differential analog input stages (Analog-Reference REF±  and Spare-Analog-Input SAIN±  on
connector J1 as shown in Figure 3.45).
 Figure 3.43:- T200 Analog Input Description
Note that:
§  Input Impedance is 10k Ω.
§  Analog input maximum voltages
Maximum input voltage wrt PE:-  30V.
Maximum differential voltage:- 30V.
§  All T200 analog inputs are isolated from high voltage circuitry internally by double insulation standard isolation,
and are considered Safety Extra Low Voltage circuitry.
§  A/D Converter resolution is 12bits:- each 4.88mV input voltage step represents 1 conversion bit.
§  An approx. 1kHz analog filter is placed before the A/D converter
§  Analog Inputs are sampled approximately every 320microseconds to 500microseconds, depending upon the
software configuration.
10kOhms 
10kOhms 
10kOhms 
10kOhms 
- 
+ 
12Bit A/D Converter
AGND 
Analog_Input +  
Analog_Input - 
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com