B.3.16.45 Current Limits
The Current Limits panel allows the user to see and set the current limit parameters.
CURRENT LIMIT PARAMETERS :
• Max. Current (combined) (A) → This is the minimum of all of the maximum currents set for the
application. This is the current used as the maximum current demand for the current loop.
• Nominal Sensed Current (A) → This is the maximum current that can be sensed by the drive –
this is set automatically at power up for the power stage being used.
• Controller Max. Current (A) → This is the maximum current (peak) available from the drive –
this is set automatically at power up for the power stage being used.
• Motor Max. Current (A) → The maximum current that can be used with the attached motor –
this is set automatically at power up for the motor being used.
• Max. Torque Limit (Nm) → This can be used to limit the maximum current to a lower value
than that obtained from the minimum of the motor and drive maximum currents. If this is not
necessary then this parameter should be set to a very high value so that it has no effect.