3.1.2  A.C. Input Line Protection 
Details  of  the  recommended  Line fuses  are  given  in  Section 2  of  this  manual. Alternatively an  AC  mains  Circuit 
Breaker  (Instantaneous  Trip  Type)  can  be  used  as  a  protective  device  providing  its  ratings  are  equivalent  to  the 
recommended fuses. 
After a power loss to the servo-drive, the motor will continue running until its stored energy is dissipated through 
friction alone, or will be stopped by a motor-equipped brake if a brake is available. 
It is also recommended to install a contactor rated for the DS2100 input between the line fuses and the EMC filter at 
the input  of the DS2100 (refer to Figure 3.1). This contactor should be controlled  directly by user supplied 
Emergency  Stop  Buttons  and  other  series  connected  safety  switches  to  remove  AC  input  power  in  any  situation 
affecting personnel safety. 
3.1.3  Line Filter Requirements 
Details of the recommended line filters for each of the DS2100 variants are given in Section 2 of this manual. 
WARNING
 - The supply-disconnecting device (circuit breaker) must be switched to 
the OFF position before any service or maintenance activity is commenced. 