PAGE 3-32         C27750-001 
3.7.1.4  Size D 
EMC Filter,
Fuses etc.
See
Section 2
Installation
 4  5 6
 L1 L2 L3
Connector J9
D
3
PE
a.c. Mains
L1
L2
L3
Protective
Earth
Figure 3.20 Size D AC Mains Input Connection 
-  Fixed connector: 4 pole, screw terminal 
-  D size wiring: cable 6 AWG (13 mm
2
) for 50/140 
-  D size wiring: cable 4 AWG ( 21mm
2
) for 60/180 
-  PE Terminal wiring: cable 6 AWG (13 mm
2
) for 50/140 
-  PE Terminal wiring: cable 4 AWG (21 mm
2
) for 60/180 
-  Stripping Length 16mm 
-  Tightening Torque: 2-2.3Nm 
Pos. 
Name 
Function 
J9.3  PE  Protective Earth Screw Terminal 
J9.4
L1 
Phase "L1", three-phase voltage input 230/460Vac ±10% 
J9.5  L2 
Phase "L2", ", three-phase voltage input 230/460Vac ±10% 
J9.6  L3 
Phase "L3", ", three-phase voltage input 230/460Vac ±10% 
Table 3.3-6 J9 AC Mains Power connector, D Size 