User`s manual
APPENDIX B – GUI  B-6 
CDS7324 (FORMERLY LSF-0819)   
Rev. A  INSTALLATION & USER’S MANUAL 
B.2.11 Event Logger 
The Event Logger is one of the four large panels in the Main Window. It is located at the bottom left of the Main 
Window, directly under the Navigator. The purpose of the Event Logger is to allow the user to record any 
parameter read and / or parameters write events. Logging events can be useful in order to see what is being read 
from or written to the controller at the lowest level. For each logged event the event type, parameter name, 
parameter number, value, status, and timestamp are logged. 
B.2.12  Event Logger Toolbar 
The Event Logger toolbar consists of the following buttons. 
Start Logging 
If the Start Logging toggle button is depressed, the Event Logger logs those events whose filter toggle buttons 
(i.e. Log Read Parameter or Log Write Parameter) also are depressed. 
Stop Logging 
If the Stop Logging toggle button is clicked, all logging is stopped. Clicking the Start Logging button can 
recommence logging. 
Clear Log 
Clicking the Clear Log button completely clears the Event Logger. 
Log Read Parameter 
The Log Read Parameter toggle button needs to be depressed if any parameter read events are to be logged. 
Log Write Parameter 
The Log Write Parameter toggle button needs to be depressed if any parameters write events are to be logged. 