Safeguards should be an integral part of a work cell design, installation, operator training, and operator 
procedures. A computer-controlled system may activate remote devices under program control at times not 
anticipated by personnel. It is critical that safeguards be in place to prevent personnel from entering the work cell 
whenever equipment power is present. Moog highly recommends the use of work cell safety features such as 
light curtains, safety gates or safety floor mats to prevent access to the workcell while power is present.  
Computer controlled systems have various communication features which may aid the user in constructing 
system safeguards, including: 
•  emergency stop circuitry 
•  binary input and output lines 
•  spare system-controlled user lines 
The emergency power-off circuitry of a computer-controlled system is generally capable of switching external 
power systems, as well as detecting intrusion signals from safety barriers. 
All personnel must observe sound safety practices during the operation and testing of all electrically powered 
equipment. To avoid injury or damage to equipment, always remove power BEFORE attempting ANY repair or 
upgrade activity. 
2.2.3  Safety Requirements for Cables 
a) Requirements - Conductors and Cables 
All cables and conductors used shall be specified as compliant with the requirements of European Standard EN 
60204-1 and other known National and International Standards for the environment in which they are installed 
and for the voltage and current carried. 
Conductors and cables shall be specified and selected so as to be suitable for the operating conditions (e.g. 
voltage, current, protection against electric shock, grouping of cables) and external influences (e.g. ambient 
temperature, presence of water or corrosive substances, mechanical stress) which can exist. 
User's whose machine installations require CE-
Compliance should read this Section. 