B.2.16.20 Continuous Bus Voltage 
The Continuous Bus Voltage panel shows the bus voltage status and allows the voltage limits to be set. 
•  Detected Bus Voltage (V) → The actual value of the bus voltage. 
•  Over Voltage Limit (V) → The bus voltage at which a bus over-voltage fault is indicated. 
•  Under Voltage Limit (V) → The bus voltage at which a bus under-voltage fault is indicated. This is read only, 
the value being set by the percentage parameter. 
•  Under Volt. Limit % of Vdc Nom. (%)→ The percentage of the nominal voltage that will be used as the under 
voltage limit. 