User`s manual
APPENDIX B – GUI  B-33 
CDS7324 (FORMERLY LSF-0819)   
Rev. A  INSTALLATION & USER’S MANUAL 
B.2.16.32 Motor Parameters 
The Motor Parameters panel allows the user to set/read the electrical parameters of the motor. 
A number of parameters are required when configuring a specific motor drive. For standard motors, these 
parameters are implemented in the GUI’s database. 
For non-standard motors, the user must enter these parameters. This can be done using this panel but it is 
preferable to set up the non-standard motor in the non-standard motor database so that it is available for future 
use. 
MOTOR PARAMETERS 
•  d-axis inductance (H) → The inductance value of d-axis. 
•  q-axis inductance (H) → The inductance value of q-axis. 
•  Terminal-Terminal resistance (Ohm) → The terminal-to-terminal resistance of the motor. 
• Ke (V/rad/s) → The Ke factor of the motor. 
•  No. of Poles → The number of motor poles. It can be set from 2 to 36. 
•  Max. Continuous RMS Current (A) → The maximum continuous RMS current of the motor. 
•  Max. Motor Speed (deg/s) → The maximum speed of the motor. 
•  Resolver Poles → The number of resolver poles. 
• Commutation offset →The value of the commutation offset. 