CHAPTER 3.0 Wiring and Installation  3-3 
CDS7324 (FORMERLY LSF-0819)   
Rev. A  INSTALLATION & USER’S MANUAL 
3.1.4  Serial Set-up Terminal (User-Supplied) 
An RS-232 interface should be established for individual servo-drive communications, using a PC. The PC can 
run Moog's WinDrive Windows-based user-interface program. 
3.1.5 Control-Backup Power Input (User Supplied) 
The DS2110 requires a control power source to supply backup-power for the control electronics. This control-
backup power is useful where the user requires that the DS2110 does not lose absolute position data or status 
information when AC mains power is removed from the DS2110. 
The user is directed to the local Moog sales office or authorised distributor for a recommended list of these control 
power source devices. 
The 24V
dc
 control power option allows high voltage motor power to be removed from a DS2110 Series Servo-
drive without losing control power. 
The acceptable voltage range for this supply is 24V
dc 
±10% with a minimum current rating of 2A
dc
 per DS2110 
Series Servo-drive connected. A low cost unregulated DC supply is adequate. 
3.1.6 Brushless Servo motors  
The DS2110 series Servo-drive is compatible with Moog brushless servomotors. 
Normal connection to the motor requires two cables - a power and a signal cable. The power cable provides 
three-phase stator power, protective earth and brake connections. The signal cable carries position transducer 
feedback signals and motor temperature detection connections. 
NOTE - The 24V
dc
 power supply must be compliant with the requirements of 
the EU EMC Directive. The 24V
dc
 output from the power supply must be Safety 
Extra Low Voltage (SELV - as defined by European standard EN 60950). 
Required for 
CE-Compliance
The personal computer using Windrive is a service engineering tool only and 
must be installed so that use of the key sequences which allow control of the 
machine functions is accessible to authorized, qualified service personnel only. 
All such service set-up computers must be CE -marked as compliant with the 
EU EMC Directive. 
Required for 
CE-Compliance
The G362-x003 &-x006 MUST have a 24V
dc
 logic backup supply connected for 
the drive to operate. No internal high voltage backup is provided on these 
smaller models. 