3.6  Sequence of Component Wiring Recommendations 
The following sequence for wiring is a recommendation. Individual wiring steps are denoted by a box character, 
which can be used as an installation check off list. 
The terminal block layout on all power supplies and servo-drives has been designed to isolate low voltage from 
high voltage circuits. Cabinet conduits should be arranged to maintain this physical separation.  
a) Power Circuit Wiring 
  Wire a 24V Logic Supply to the drive (Required on A size drives). Fit a suitable EMC filter on the 24V logic 
Supply and fuse. 
  Wire a 24V Logic Supply to the drive for fan external supply, if necessary. 
  Wire a.c. mains input to user supplied fuses. Make a secure and reliable connection between the chassis of 
the equipment and Earth. 
  Fit a suitable EMC Mains Line Filter after the User supplied fuses and contactor. 
  Wire a.c. mains from the user-supplied contactor to the power input poles of the DS2110. 
b) Servo-drive Wiring 
  Plug in Axis I/O cable to J2 and connect other end to user I/O equipment. 
  Plug in resolver cable at J3 (or Encoder Cable to J4). 
  Connect appropriate communications cabling (RS232 at J1, and/or Field Bus). 
c) Motor Wiring 
  Repeat the steps listed in this Section for each motor in the system. 
  Plug in and screw tight resolver/encoder cable to motor position connector. 
  Plug in and screw tight motor power cable to motor power connector. Also connect the brake terminations at 
J2D (if provided). 
  Connect motor power cable to appropriate drive power terminals. 