User`s manual
CHAPTER 3.0 Wiring and Installation  3-34
CDS7324 (FORMERLY LSF-0819)   
Rev. A  INSTALLATION & USER’S MANUAL 
3.9.3  C Size Regeneration Resistor connection 
Tie screen to 
panel on 
which resistor 
is mounted. 
Tie Screen to 
chassis via EMC 
bracket. See 
Section 2 
Installation 
 J6.4 J6.5 
+ATP RR 
Connector J6 
DS2110 C 
Recovery 
Resistor 
Figure 3.27 DS2110 Size C External Regeneration Connections 
J6 
-  Fixed connector: 5 pins, male connector 
-  Mating connector, 5 pins, female, crimped supplied with the drive. (Molex 42816-0512) 
-  C size wiring: cable 8 AWG (8.4 mm
2
). 
Pos. Name  Function 
J6.4  +ATP  DC Bus (+) 
J6.5 RR  Regeneration Resistor 
Table 3. -12 J6, Regeneration Resistor connector, C Size 
3.9.4  D Size Regeneration Resistor connection 
Tie screen to 
panel on 
which resistor 
is mounted. 
Tie Screen to 
chassis via EMC 
bracket. See 
Section 2 
Installation 
 J9.2 J9.1 
+ATP RR 
Connector J9 
DS2110 D 
Recovery 
Resistor 
Figure 3.28 DS2110 Size D External Regeneration Connections 
J9 
-  Fixed connector: 2 pole, screw terminal 
-  D size wiring: cable 6 AWG (13 mm
2
) for 50/140 
-  D size wiring: cable 4 AWG ( 21mm
2
) for 60/180 
-  Stripping Length 16mm 
-  Tightening Torque: 2-2.3Nm 
Pos. Name  Function 
J9.1 RR  Regeneration Resistor 
J9.2  +ATP  DC Bus (+) 
Table 3. -13 J9, Regeneration Resistor connector, D Size 