User`s manual
CHAPTER 3.0 Wiring and Installation  3-58
CDS7324 (FORMERLY LSF-0819)   
Rev. A  INSTALLATION & USER’S MANUAL 
3.13.4 D Size Power Stage 
-  Fixed connector: 12 pole, screw terminal 
-  D size wiring: cable 6 AWG (13 mm
2
) for 50/140 
-  D size wiring: cable 4 AWG ( 21mm
2
) for 60/180 
-  PE Terminal wiring: cable 6 AWG (13 mm
2
) for 50/140 
-  PE Terminal wiring: cable 4 AWG (21 mm
2
) for 60/180 
-  Stripping Length 16mm 
-  Tightening Torque: 2-2.3Nm 
Pos. Name  Function 
J9.1 RR  Regeneration Resistance 
J9.2  +ATP  DC Bus (+) 
J9.3  PE  Protective Earth Screw Terminal 
J9.4  U1 
Phase "L1", three-phase voltage input 230/460Vac ±10% 
J9.5 V1 
Phase "L2", ", three-phase voltage input 230/460Vac ±10% 
J9.6 W1 
Phase "L3", ", three-phase voltage input 230/460Vac ±10% 
J9.7 U2  Motor Phase U 
J9.8 V2  Motor Phase V 
J9.9 W2  Motor Phase W 
J9.10  PE  Motor Protective Earth 
J9.11  +AT  DC Bus (+) 
J9.12  -AT  DC Bus (-) 
-  Fixed connector: 2 pins, male connector 
-  Mating connector, 2 pins, female, supplied with the drive. Wago (Part # 231-102/026-000) 
-  D size wiring: cable 14 AWG (2.1 mm
2
). 
-  Stripping Length 8mm 
Pos. Name  Function 
J8.1  24V  +24V Logic Backup Supply 
J8.2  0V  Logic Supply Return 