User`s manual
CHAPTER 3.0 Wiring and Installation  3-59
CDS7324 (FORMERLY LSF-0819)   
Rev. A  INSTALLATION & USER’S MANUAL 
3.13.5 E Size Power Stage 
-  Fixed connector: 14 pole, screw terminal 
-  Pos 1,2: Cable 14 AWG (2.1 mm
2
) , Stripping 9mm , Torque 0.7Nm 
-  Pos 3,4: Cable 2 AWG (34 mm
2
) , Stripping 19mm , Torque 4Nm 
-  Pos 5-14: Cable 1 AWG (42 mm
2
) , Stripping 24mm , Torque 8Nm 
Pos. Name  Function 
J9.1 24V fans 
Voltage inputs 24Vdc fans ±10%, 2A 
J9.2  0V fans   
J9.3 RR  Regeneration Resistance 
J9.4  +ATP  DC Bus (+) 
J9.5  PE  Protective Earth Screw Terminal 
J9.6 U1 
Phase "L1", three-phase voltage input 230/460Vac ±10% 
J9.7 V1 
Phase "L2", ", three-phase voltage input 230/460Vac ±10% 
J9.8 W1 
Phase "L3", ", three-phase voltage input 230/460Vac ±10% 
J9.9  PE  Motor Protective Earth 
J9.10  U2 Motor Phase U 
J9.11  V2 Motor Phase V 
J9.12 W2  Motor Phase W 
J9.13  +AT  DC Bus (+) 
J9.14  -AT  DC Bus (-) 
-  Fixed connector: 2 pins, male connector 
-  Mating connector, 2 pins, female, supplied with the drive. Wago (Part # 231-102/026-000) 
-  E size wiring: cable 14 AWG (2.1 mm
2
). 
-  Stripping Length 8mm 
Pos. Name  Function 
J8.1  24V  +24V Logic Backup Supply 
J8.2  0V  Logic Supply Return 