Instruction manual
MM
2
AWG
,5 ,75 1,0 1,5 2,5 4 6
22 20 18 16 14 12 10
  The beam angle may be adjusted on the 
bottom of the unit.
•  Éstos se recomiendan las distancias máximas para 
12VDC con una gota del voltage del 10%.
•  Ceux-ci sont recommandés des distances maximum 
pour 12VDC avec une chute de tension de 10%.
•  Diese werden maximale Abstände für 12VDC mit 
einem 10% Spannungsabfall empfohlen.
•  Estes são recomendados distâncias máximas para 
12VDC com uma queda de tensão de 10%.
•  Questi sono suggeriti distanze massime per 12VDC 
con una differenza de potenziale di 10%.
12
These are recommended maximum distances
for 12VDC with a 10% voltage drop.
19
RJ45
BNC
24VAC
1
2
3
4
Camera
Camera
Heater/Blower
Heater/Blower
Red
Orange
Yellow
Green
POWER
Max 40 Watts
52 Watts 
1/0
1
2
3
4
Alarm 1
Alarm 2
Alarm 3
Common
Blue
Violet
Gray
White
 Make the appropriate male and female connections. Indoor model does not include pre-run cables.
•  Haga las conexiones masculinas y femeninas apropiadas. El modelo de interior no incluye pre-funciona los cables.
•  Établissez les rapports masculins et femelles appropriés. Le modèle d'intérieur n'inclut pas pré-courent des câbles.
•  Stellen Sie die passenden männlichen und weiblichen Beziehungen her. Innenmodell schließt nicht vor-laufen lassen Kabel 
ein.
•  Faça as conexões masculinas e fêmeas apropriadas. O modelo indoor não inclui pre-funciona cabos.
•  Faccia i collegamenti maschii e femminili adatti. Il modello dell'interno non include pre-fa funzionare i cavi.
Power and Control Inputs (Outside of Housing)
POWER
1    Camera Power (+ 12 VDC)    Red
2    Camera Power (- 12 VDC)    Orange
3    Accessory Power (+12 VDC)    Yellow
4    Accessory Power (-12 VDC)    Green
CONTROL RJ45 Ethernet Connector
17
Make the appropriate male and female connections. 
Indoor model does not include 
pre-run cables. 
•  Haga las conexiones masculinas y femeninas apropiadas. El modelo 
de interior no incluye pre-funciona los cables.
•  Établissez les rapports masculins et femelles appropriés. Le modèle 
d'intérieur n'inclut pas pré-courent des câbles.
•  Stellen Sie die passenden männlichen und weiblichen Beziehungen 
her. Innenmodell schließt nicht vor-laufen lassen Kabel ein.
•  Faça as conexões masculinas e fêmeas apropriadas. O modelo indoor 
não inclui pre-funciona cabos.
•  Faccia i collegamenti maschii e femminili adatti. Il modello dell'interno 
 non include pre-fa funzionare i cavi. 
1  Camera Power (+12 VDC)   Red
2  Camera Power (-12 VDC)   Orange
POWER
Power and Control Inputs (Inside of Housing)
18