User manual
7 Operation Performing Functions Tests
© 2010 Moog GmbH User Manual RKP-II (CA53461-001; Version 2, January 2010) 49
7.1.2.6 Limiting the Maximum Flow
Fig. 27: Limiting the Maximum Flow
7.2 Performing Functions Tests
Performing Functions 
Tests
Pre-Conditions:
• Initial set-up of the pump is complete: Ö Chap. "7.1 Initial Pump Set-Up", 
Page 43
• The end caps on the through drive of the pump stages have been 
removed.
• It has been assured that the pump is being supplied with operating fluid.
• The pump has been visually inspected, with particular attention given to 
the lines and port connections.
Procedure:
1. Carry out the functions test in accordance with the instructions provided 
by the machine / equipment manufacturer.
Pos. Description
1 Adjustment mandrel
2 Cap nut
3 Lock nut
Displacement 
V [cm
3
/R] 1932456380100 140
Pos.1 WS 8 WS 12 WS 10
Pos. 2 WS 24 = 40 Nm + 
10 Nm
WS 32 = 80 Nm + 
10 Nm
WS 27 = 80 Nm + 
10 Nm
Pos. 3 WS 24 = 50 Nm + 
10 Nm
WS 32 = 90 Nm + 
10 Nm
WS 27 = 90 Nm + 
10 Nm
ΔV for 1 mm 
adjusting 
screw travel 
(pitch 
1.5 mm/R)
3.6 5.6 6.5 8.9 11.3 11.5
Tab. 13: Adjustments Limiting the Maximum Flow
The functions tests is performed to ensure that the pump has been 
installed into the machine / equipment properly.