To Cancel All Zone Bypasses
I. Press the Bypass (#) key followed by key “9"
2. All ZONE indicators will stop flashing. The zones are returned to operation.
To Bypass All Faulted Zones Simultaneously (Not available in U.L. Listed
Systems)
1. The system must be disarmed.
2. Press the Bypass (#) key, then press the "0" key.
3. All faulted zones will simultaneously be bypassed. The corresponding
ZONE indicators will blink to indicate zones that have been bypassed.
The blinking will cease 30 seconds after the system is armed.
Key Switch Operation
Your system may utilize a conventional key switch for arming and disarming the
system. Arming and disarming with a key switch is performed as follows:
Arming
1. Verify that the READY light is on.
2. Insert your key into the key switch and turn. Hold for one se-
cond and release.
3. The red ARMED light will blink during the exit delay cycle then light
steady when the system arms.
Disarming
1. Insert your key into the key switch and turn. Hold for one second and
release.
2. The red ARMED light will go out, indicating that the system is
disarmed.